Desa CGEFP33PR, CGEFP33NR, EFP33PR, EFP33NR, VTGF33NR, VTGF33PR Troubleshooting, Observed Problem

Models: CGEFP33PR, CGEFP33NR, EFP33PR, EFP33NR, VTGF33NR, VTGF33PR

1 50
Download 50 pages 37.73 Kb
Page 29
Image 29
TROUBLESHOOTING

TROUBLESHOOTING

29

TROUBLESHOOTING

Note: For additional help, visit DESA International’s technical service web site at www.desatech.com.

Note: All troubleshooting items are listed in order of operation.

OBSERVED PROBLEM WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.

POSSIBLE CAUSE CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

When buttons on remote control are pressed,

1.

Battery in remote control is either miss-

1.

Replace battery in remote control

there is no response from fireplace

 

ing or has low power

 

 

 

 

2.

Remote control is not pointed toward

2.

Point remote control toward lower front

 

 

fireplace

 

panel of fireplace when operating

 

3.

Manual ignition bypass switch not in

3.

Place manual ignition bypass switch in

 

 

OFF position

 

OFF position

 

4.

No power available to fireplace

4.

Make sure power cord is plugged into

 

 

 

 

electrical outlet and outlet has power

 

5.

Ignitor electrode not connected to igni-

5.

Reconnect ignitor cable

 

 

tor cable

 

 

 

 

6.

Broken ignitor cable

6.

Replace ignitor cable

 

7.

Ignitor electrode broken

7.

Replace pilot assembly

 

8.

Ignitor electrode positioned wrong

8.

Replace pilot assembly

 

 

 

 

 

 

When wall switch button is pressed, there is

1.

No power available to fireplace

1.

Make sure power cord is plugged into

no response from fireplace

 

 

 

an electrical outlet and outlet has power

 

2.

Manual ignition bypass switch not in

2.

Place manual ignition bypass switch in

 

 

OFF position

 

OFF position

 

3.

Wall switch wire harness is disconnected

3.

Check continuity of wall switch wire

 

 

 

 

harness. Make sure plug on wall switch

 

 

 

 

wire harness is fully inserted into socket

 

 

 

 

on circuit board in fireplace. Replace if

 

 

 

 

necessary

 

 

 

 

 

 

Burner does not light after ODS/pilot is lit

1.

Burner orifice clogged

1.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 28) or replace burner orifice

 

2.

Inlet gas pressure is too low

2.

Contact local gas company

 

 

 

 

 

 

Delayed ignition burner

1.

Manifold pressure is too low

1.

Contact local gas company

 

2.

Burner orifice clogged

2.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 28) or replace burner orifice

 

 

 

 

 

 

Burner backfiring during combustion

1.

Burner orifice is clogged or damaged

1.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 28) or replace burner orifice

 

2.

Damaged burner

2.

Replace damaged burner

 

3.

Gas regulator defective

3.

Replace regulator

 

 

 

 

 

 

Slight smoke or odor during initial operation

1.

Not enough air

1.

Check burner for dirt and debris. If

 

 

 

 

found, clean burner (see Cleaning and

 

 

 

 

Maintenance, page 28)

 

2.

Gas regulator defective

2.

Replace regulator

 

3.

Residues from manufacturing processes

3.

Problem will stop after a few hours of

 

 

and logs curing

 

operation

 

 

 

 

 

 

Moisture/condensation noticed on windows

1.

Not enough combustion/ventilation air

1.

Refer to Air for Combustion and Venti-

 

 

 

 

lation requirements (page 5)