12.After heater is secured, replace mantel on hearth base (see Figure 25). Make sure mantel is flush against wall. In- stall brass trim (see page 7).
Cabinet
Mantel
Figure 24 - Installing Cabinet Mantel
| Actual | Framing |
|
|
|
Height | 32 3/8" | 33" |
Front Width | 34 5/16" | 34 3/4" |
Depth | 16 11/16" | 17 3/4" |
1.Frame in rough opening. Use dimen- sions shown in Figure 26 for the rough opening.
If installing in a corner, use dimensions shown in Figure 27 for the rough open- ing. The height is 33" which is the same as the wall opening in Figure 26.
2.If using optional blower, install it now. Also install and properly ground GA3555 three prong 120 volt outlet in fireplace. Follow instructions included in kits.
3.Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the manual shutoff valve. The flexible gas line must be the last item installed on the gas piping. See In- stalling Gas Piping to Fireplace Loca- tion, page 14.
4.Carefully set fireplace in front of rough opening with back of fireplace inside wall opening.
5.Attach flexible gas line to fireplace gas regulator. See Connecting Fireplace to Gas Supply, page 15.
6.Carefully insert fireplace into rough opening.
7.Attach fireplace to wall studs using nails or wood screws through holes in nailing flange (see Figure 28).
8.Check all gas connections for leaks. See Checking Gas Connections, pages 15 and 16.
9.If using optional GA7090 Brass Trim Kit, install brass trim after final finish- ing and/or painting of wall (see Figure 6, page 7).
Nails or
Wood
Screws
Figure 25 - Inserting Fireplace Into Cabinet Mantel
BUILT-IN FIREPLACE
INSTALLATION (Check Local
Building Codes)
17 3/4"
33"
34 3/4"
Figure 26 - Rough Opening for Installing in Wall
39 3/8"
27 7/8"
34 3/4" 55 5/8"
Figure 27 - Rough Opening for Installing in Corner
Nailing
Flanges
Figure 28 - Attaching Fireplace to Wall Studs
Continued
103413 | 13 |