Desa INSTALLING GA3650T BLOWER ACCESSORY, For CGFP28P Model Only, CGFP28N and CGFP28NT

Models: CGFP28NT CGFP28N

1 32
Download 32 pages 6.41 Kb
Page 8
Image 8
INSTALLING GA3650T

(For CGFP28P Model Only)Manual backgroundManual background CGFP28N and CGFP28NT

UNVENTED (VENT-FREE) NATURAL GAS FIREPLACE

INSTALLATION

Continued

INSTALLING GA3650T

BLOWER ACCESSORY

(For CGFP28P Model Only)

NOTICE: Shut-off gas supply and disconnect heater from gas sup- ply. Contact a qualified service person to do this.

1.Remove fireplace screen (see Figure 7).

Manual background WARNING: You must operate this fireplace with the fireplace screen in place. Make sure fire- place screen is in place before running fireplace.

2.If logs are installed, carefully remove the logs and set aside, noting the prop- erly mounted location of each.

3.Remove screws that attach log base as- sembly to fireplace (do not discard). Carefully lift up log base assembly and remove from fireplace, taking care to pull flexible gas line through the ac- cess holes (see Figure 8).

Manual background CAUTION: Do not pick up log base assembly by burners. This could damage burners. Only handle base by grates.

4.Place the blower against lower rear wall of firebox outer wrapper with the ex- haust port directed upward. Align the holes in top mounting tabs of blower with holes in wall of wrapper (see Fig- ure 9). Using two #8 screws provided, mount blower and tighten screws firmly.

5.Route terminals end of power cord through large hole near top of left floor support bracket. Make sure to pass the cord from the outside (left side) towards the center of firebox (see Figure 10).

6.Using two #6 screws provided attach power cord mounting plate to the out- side face of left floor support bracket. Drive screws from inside (right side) of floor support bracket. Attach the plate so that the power cord is directed

towards rear of firebox (see Figure 10). Tighten screws firmly.

7.Remove the three screws (do not dis- card) and cover plate from center of firebox wrapper rear wall. Discard this cover plate.

8.Mount the supplied thermostatic switch and cover assembly into firebox wrap- per wall. Do this by feeding terminal ends of wire harness into the hole. Al- low wires to fall to bottom of firebox cavity (see Figure 11).

9.Using three screws from step 7, attach switch and cover assembly to firebox wrapper rear wall. Tighten screws firmly (see Figure 11).

10.Mount selector switch to front flange of left floor support bracket. Align graphics on switch upright and push firmly to snap switch into rectangular hole. Push the selector switch to the off (middle) position (see Figure 10).

Manual background WARNING: Failure to connect all wires properly as indicated may cause electrical short circuit or personal injury. A qualified electrician should check that all connections are made properly.

Notches

Screen Mounting Screws

Figure 7 - Removing Fireplace Screen

Screws

Log Base

Flexible Gas Line

Figure 8 - Removing Log Base from Fireplace

Exhaust

Port

#8 Screws

Blower

Lower Rear

Wall of Firebox

Figure 9 - Mounting Blower to Firebox

Selector

 

 

Wire

ON

1

Clips

 

AUTO

3

 

 

OFF

2

 

Switch

 

#6 Screws

#10 Screw

 

 

Figure 10 - Installing Power Cord, Mounting Plate, and Selector switch

Switch and Cover Assembly

Figure 11 - Installing Switch and Cover Assembly

8

103413

Page 8
Image 8
Desa INSTALLING GA3650T BLOWER ACCESSORY, For CGFP28P Model Only, CGFP28N and CGFP28NT, Installation, Continued