OWNER’S MANUAL

INSTALLATION

Continued

11. Install three plastic wire clips provided

 

into floor support bracket (see Figure

 

10, page 8). Secure by pushing clips

 

firmly into holes.

12. Attach green ground wire ring terminal

 

to floor support bracket using #10 sheet

 

metal grounding screw provided (see

 

Figure 10, page 8). Tighten screw firmly.

13.

Attach all five remaining wiring terminals

 

to the appropriate switch or motor termi-

 

nal. Carefully note the correct color cod-

 

ing (see Figures 12 and 14). Push female

 

wire terminals fully onto male terminal.

14.

Secure wires into the appropriate plas-

 

tic wire clips (see Figure 12).

15.

Plug in blower power cord.

 

If your fireplace system is installed

 

as a freestanding unit with an acces-

 

sory mantel, install one plastic bush-

 

ing (provided) into the 1.5" hole in the

 

lower left side of the outer casing (see

 

Figure 13). Route power cord through

 

plastic bushing. Plug the power cord

 

into a properly grounded three-prong

 

wall receptacle near the firebox.

 

If your fireplace system installation is

 

recessed, install one plastic bushing pro-

 

vided into the 1.5" hole near the middle of

 

the left floor support bracket (see Figure

 

13). Route power cord through plastic

 

bushing. Plug the power cord into a prop-

 

erly installed duplex outlet. (If an outlet is

 

not available, the accessory model

 

GA3555 Outlet Kit with cover can be in-

 

stalled in your fireplace. This will supply

17.Peel off the backing paper and stick the supplied wiring diagram decal on the firebox bottom approximately 12" in front of blower.

18.Replace log base assembly in fireplace. Feed flexible gas supply line into fire- place base area while replacing log base assembly. Make sure the entire flexible gas line is in fireplace base area.

Note: If firebrick is installed, make sure the back of the firebox bottom slides under the rear panel of the firebrick. (lift the firebrick up if necessary.)

IMPORTANT: Do not pick up log base assembly by burners. This could damage burners. Only handle base by grates.

19.Reattach log base assembly to fireplace with screws removed in step 3.

20.Install logs and fireplace screen per in- structions in operating manual provided with fireplace.

WARNING: Failure to position the parts in accordance with sup- plied diagrams or failure to use only parts specifically approved with this heater may result in dam- age or personal injury.

21.Connect gas supply to fireplace per in- structions in operating manual provided with fireplace.

NOTICE: A qualified service per- son must connect fireplace to gas supply. Follow all local codes.

If any of the original wire as supplied with the appliance must be replaced, it must be replaced with 105˚C wire or it's equivalent.

Bushing Location for

Freestanding Installation

Bushing Location for Recessed Installation

Figure 13 - Installing Bushings

Fan Switch

(Off/On/Auto)

1Auto

Off

2

Red

Fan

3

Switch

 

 

110/115

 

 

(N.O.)

On

 

Blower

V.A.C.

 

Black

 

 

Motor

Green

Blue

 

 

White

 

 

 

Figure 14 - Wiring Diagram

OPERATING THE BLOWER

Light your gas appliance with the blower off. After about 5 minutes, turn the blower on to deliver heated air at the top louvers. The thermostatic ally-controlled blower fea- tures a three position switch. The three set- tings are: ON, OFF, and AUTO. In the ON position, the blower will operate constantly. In the OFF position, the blower will not operate. In the AUTO position, the blower

a convenient three-prong grounded elec-

trical outlet for your blower. Refer to the

installation manual provided with the

model GA3555 accessory for instructions

on wiring the duplex outlet.)

16. Check to make sure that the power cord

and wires are completely clear of the

blower wheel and that there are no other

foreign objects in blower wheel. Turn

Note: To prevent short circuit, white wire MUST be connected to motor.

Blue

Wire

Blue

Wire

To Switch and Cover Assembly

will start when the thermostat senses a suf- ficient increase in firebox temperature.

Note: Your gas logs and thermostat blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modu- lates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.

blower on by pushing the selector switch

to the on position and check for opera-

tion. Turn blower off before continuing.

WARNING: Never touch the blower wheel while in operation.

 

 

White

AUTO

3

Wire

OFF

2

Green

ON

1

Red Wire

Black Wire

Wire

Figure 12 - Wire Attachment

Note: It is safe to operate fireplace with blower turned off. However, the blower helps distribute heated air from the fireplace.

Note: Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions.

103413

9

Page 9
Image 9
Desa CGFP28NT installation manual Operating the Blower, Metal grounding screw provided see

CGFP28NT, CGFP28N specifications

The Desa CGFP28NT and CGFP28N are state-of-the-art gas fireplaces designed to enhance the ambiance and comfort of any living space. These models are recognized for their combination of aesthetic appeal and advanced technology, providing users with a reliable and efficient heating solution.

One of the main features of both the CGFP28NT and CGFP28N is their sleek design, which seamlessly integrates into various décor styles. Their clean lines and modern look allow them to serve as a focal point in the room while providing warmth and comfort. The large viewing windows offer an unobstructed view of the flames, creating an inviting atmosphere.

Technologically, both models are equipped with the latest innovations to ensure optimal performance. The CGFP28NT features an advanced electronic ignition system, which guarantees a quick and reliable start every time. This system minimizes gas usage and allows for consistent temperature control, making it both environmentally friendly and cost-effective.

The CGFP28N is designed with a unique heat exchanger that maximizes heat output while maintaining safety. This technology ensures that the fireplace operates efficiently, distributing warmth evenly throughout the room without overheating the unit itself. Additionally, both models incorporate a variable flame control feature, allowing users to adjust the intensity of the fire according to their needs.

Another key aspect of the CGFP28NT and CGFP28N is their user-friendly interface. Both models come with a remote control, enabling users to operate the fireplace from the comfort of their couch. This added convenience is paired with straightforward installation requirements, making it accessible for a wide range of customers.

Safety is a top priority for Desa, and these models feature an automatic shut-off valve that activates in case of any irregularities, ensuring peace of mind for homeowners. They also have a durable construction that withstands the test of time, making them a wise investment for those seeking a dependable heating source.

In summary, the Desa CGFP28NT and CGFP28N gas fireplaces offer a perfect blend of style, technology, and safety. With their eye-catching designs, advanced features, and user-friendly operation, they are an excellent choice for anyone looking to enhance their home with the warmth and beauty of a gas fireplace.