Desa CGN10 installation manual Checking Gas Connections, Connecting To Gas Supply, Continued

Models: CGN10

1 28
Download 28 pages 57.17 Kb
Page 14
Image 14
CHECKING GAS CONNECTIONS

CONNECTING TO GAS SUPPLY

Continued

CHECKING GAS CONNECTIONS

14

IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/or fittings.

 

 

 

Pressure

 

 

 

Regulator

3/8" NPT

 

 

 

 

Pipe Nipple

 

 

 

 

 

 

Heater

 

 

 

Cabinet

 

Ground Joint Union

Tee Joint

 

 

 

 

 

Manual Shutoff Valve *

Reducer

 

Test

 

 

From Gas Meter

Bushing to

Gauge

1/8" NPT

Connection *

(4" W.C. to

 

 

1/8" NPT

 

 

10.5" W.C. Pressure)

 

 

 

Plug Tap

 

 

3" Minimum

Tee

 

 

 

Joint

 

 

 

 

Pipe

Sediment Trap

 

Nipple

 

 

 

 

Cap

 

 

 

Figure 12 - Gas Connection

*An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessory, page 25.

WARNING

WARNING ICON

G 001

Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once.

WARNING

WARNING ICON

G 001

Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG

1.Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.

2.Cap off open end of gas pipe where manual shutoff valve was connected.

3.Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter.

099404

Page 14
Image 14
Desa CGN10 Checking Gas Connections, Connecting To Gas Supply, Continued, Pressure Testing Gas Supply Piping System