Desa CGN10 Trouble- Shooting, Continued, Observed, Possible, Remedy, Problem, Cause

Models: CGN10

1 28
Download 28 pages 57.17 Kb
Page 22
Image 22
Cleaning and Mainte-

TROUBLE- SHOOTING

OBSERVED

POSSIBLE

REMEDY

PROBLEM

CAUSE

 

 

 

Continued

Burner does not light after ODS/pilot is lit

1.Burner orifice is clogged

2.Burner orifice diameter is too small

3.Inlet gas pressure is too low

1.Clean burner orifice (see Cleaning and Mainte- nance, page 20) or replace burner orifice

2.Replace burner orifice

3.Contact local natural gas company

Delayed ignition of

1.

Manifold pressure is

1.

Contact local natural gas

 

 

burner

 

too low

 

company

 

 

 

 

2.

Burner orifice is

2.

Clean burner orifice (see

 

 

 

 

 

clogged

 

Cleaning and Mainte-

 

 

 

 

 

 

 

nance, page 20) or

 

 

 

 

 

 

 

replace burner orifice

 

 

 

 

 

 

 

 

 

 

Burner backfiring

1.

Burner orifice is

1.

Clean burner orifice (see

 

 

during combustion

 

clogged or damaged

 

Cleaning and Mainte-

 

 

 

 

 

 

 

nance, page 20) or

 

 

 

 

 

 

 

replace burner orifice

 

 

 

 

2.

Burner damaged

2.

Replace burner

 

 

 

 

3.

Gas regulator defective

3.

Replace gas regulator

 

 

 

 

 

 

 

 

 

Yellow flame during

1. Not enough air

1.

Check burner for dirt

 

 

burner combustion

 

 

 

and debris. If found,

 

 

 

 

 

 

 

clean burner (see

 

 

 

 

 

 

 

Cleaning and Mainte-

 

 

 

 

 

 

 

nance, page 20)

 

 

 

 

2.

Gas regulator defective

2.

Replace gas regulator

 

 

 

 

 

 

 

 

 

Slight smoke or odor

1. Residues from manu-

1.

Problem will stop after a

 

 

during initial opera-

 

facturing processes

 

few hours of operation

 

 

tion

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

Heater produces a whistling noise when burner is lit

1.Turning control knob to HIGH position when burner is cold

2.Air in gas line

3.Air passageways on heater blocked

4.Dirty or partially clogged burner orifice

1.Turn control knob to LOW position and let warm up for a minute

2.Operate burner until air is removed from line. Have gas checked by local natural gas com- pany

3.Observe minimum installation clearances (see Figure 4, page 10)

4.Clean burner (see Cleaning and Mainte- nance, page 20) or replace burner orifice.

099404

Page 22
Image 22
Desa CGN10 Trouble- Shooting, Continued, Observed, Possible, Remedy, Problem, Cause, Cleaning and Mainte