Desa CHDV37N/P Horizontal Termination Configurations, Direct-Vent Fireplace Natural/Propane/Lp

Models: CHDV37N/P

1 38
Download 38 pages 55.84 Kb
Page 10
Image 10
Horizontal Termination

Manual backgroundManual backgroundManual background CHDV37N/P(A,B) AND CHDV41N/P(A,B)

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

VENTING INSTALLATION

Continued

Horizontal Termination

Configurations

Figures 16 through 20 show different con- figurations for venting with horizontal ter- mination. Each figure includes a chart with vertical minimum/maximum and horizon- tal maximum dimensions which must be met. Seal all connections with high tem- perature silicone sealant (outer pipe only) as specified in the second warning statement on page 7. All horizontal terminations re- quire 1/4" rise per 12" of horizontal run.

UP

CBGFVK Vent Kit Shown (recommended for use with cabinet mantel)

Horizontal Venting

Vertical (V)

Horizontal (H)

37" min.

10" max.

Figure 16 - Horizontal Termination Configuration for Rigid Venting

UP

Horizontal Venting

Vertical (V)

Horizontal (H)

44" min.

29" max.

(30° and 90° only, no vertical pipe)

55" min.

41" max.

(30° elbow, 1' vertical pipe, 90° elbow)

67" min.

60" max.

79" min.

84" max.

96" min.

20' max.

Note: This configuration for use with corner installation.

CBVK Vent Kit Shown

Figure 17 - Horizontal Termination Configuration for Rigid Venting Using One 90° Elbow

Horizontal Venting

See information in

 

Figure 17 for

 

Vertical(V) and

 

Horizontal(H) maxi-

UP

mums and mini-

 

 

mums. The same

 

amounts apply for

 

flexible venting. (A

 

higher termination

 

mounting location is

 

desirable.)

 

Note: Figure 16

 

applies to rigid

 

venting only.

 

Figure 18 - Horizontal Termination Using Flexible Venting