Desa CHDV41N/P, CHDV37N/P Replacement Parts, Wiring Diagram, Service Hints, Technical Service

Models: CHDV37N/P

1 38
Download 38 pages 55.84 Kb
Page 31
Image 31
REPLACEMENT PARTS

OWNER’S MANUAL

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized retailers of this product. If they can not supply original replacement part(s), call DESA International’s Techni- cal Service Department at 1-800-DESA LOG (1-800-337-2564).

When calling DESA International, have ready

your name

your address

model and serial numbers of your fireplace

how fireplace was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

WIRING DIAGRAM

PARTS UNDER WARRANTY CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

 

 

Variable

Fan Switch

 

 

Fan Switch

 

 

 

 

(N.O.)

 

 

Off 1

2

Black

 

 

 

On

 

Blue

 

 

 

 

 

 

 

 

 

110/115

 

 

 

 

V.A.C.

 

 

 

 

 

Black

 

Blower

 

 

 

 

 

 

White

 

Motor

Green

Figure 55 - Blower Wiring Diagram for Thermostat-Controlled Models

Usually, we will ask you to return the defec- tive part to the factory.

PARTS NOT UNDER

WARRANTY

Contact authorized retailers of this product. If they can not supply original replacement part(s), call DESA International’s Parts Department at 1-800-972-7879 for referral information.

When calling DESA International, have ready

model number of your fireplace

the replacement part number

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

fireplace will not produce specified heat

propane/LP gas supply might be low (propane/LP units only)

When Gas Quality Is Bad

pilot will not stay lit

burners will produce flames and soot

fireplace will backfire when lit

If you feel your gas pressure is too low or gas quality is bad, contact your local natural or propane/LP gas supplier.

TECHNICAL

SERVICE

You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564).

You can also visit DESA International’s technical service web site at www.desatech.com.

105542

31

Page 31
Image 31
Desa CHDV41N/P Replacement Parts, Wiring Diagram, Service Hints, Technical Service, Parts Under Warranty, Owner’S Manual