![](/images/new-backgrounds/1053274/5327437x1.webp)
VENTING INSTALLATION
Installation for Vertical Termination (Cont.) High Altitude Installation Parts List for Venting Kits and Components
19
VENTING INSTALLATION
Continued
Vertical Venting
V = 40' (12.19 m) max.
Note: Install restrictor into 4" (10.16 cm) collar of burner system as shown.
Figure 41 - Vertical Venting Configuration With No Horizontal Run
HIGH ALTITUDE INSTALLATION
Your cast iron stove and
When installing this stove at an elevation above 2000 feet (in the USA), you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Reduce input 4% for each 1000 feet (304.8 m) above sea level. Check with your local gas company for proper orifice size identification and proper orifice for your location..
When installing this stove at an elevation above 4500 feet (1.37 km) (in Canada), check with local authorities.
For assistance with any high altitude installation contact DESA's Technical Service Department at
PARTS LISTS FOR VENTING KITS AND COMPONENTS
Number Description
VKG-47-K Ground Floor Vent Kit, Black
Includes: Horizontal Square Termination, 90° Elbow,
VKB-47-K Basement Vent Kit
Includes: Horizontal Square Termination, 90° Elbow,
VKS-47-K Snorkel Vent Kit
Includes: 36" (0.91 m) Snorkel Termination, 90° Elbow,
VKR-47-K Roof Vent Kit
Includes: Vertical High Wind Termination, Flue Re- strictor,
6" (15.24 cm) Black Coaxial Pipe (1 pk) | |
90° Elbow (1 pk) | |
45° Elbow (1 pk) | |
6" (15.24 cm) Adaptor Collar, Black (1 pk) | |
Wall Strap (1 pk) | |
Storm Collar (1 pk) | |
Vertical Round Termination (1 pk) | |
Wall Firestop (1 pk) | |
Vertical Restrictor (1 pk) | |
Firestop Plate (1 pk) | |
Horizontal Square Termination (1 pk) | |
Cathedral Ceiling Support Box (1 pk) | |
Roof Flashing 0 to 6/12 Pitch (1 pk) | |
Roof Flashing 6/12 to 12/12 Pitch (1 pk) | |
Vinyl Siding Standoff (1 pk) | |
Trim Plate, Black (1 pk) | |
Horizontal Round Termination (1 pk) | |
14" (0.36 m) Snorkel Termination (1 pk) | |
36" (0.91 m) Snorkel Termination (1 pk) |
For morevisit www.
.com