www.desatech.com 113261-01A
16
CLEANING AND MAINTENANCE

WARNING: Turn off heater

and let cool before cleaning.

CAUTION: You must keep con-

trol areas, burner and circulating

air passageways of heater clean.

Inspect these areas of heater

before each use. Have heater

inspected yearly by a qualified

service person. Heater may need

more frequent cleaning due to

excessive lint from carpeting,

bedding material, pet hair, etc.

WARNING: Failure to keep

the primary air opening(s) of

the burner(s) clean may result in

sooting and property damage.

ODS/PILOT AND BURNER

Use a vacuum cleaner, pressurized air or small,
soft bristled brush to clean.

BURNER PILOT AIR INLET

The primary air inlet holes allow the proper
amount of air to mix with the gas. This provides a
clean burning flame. Keep these holes clear of dust,
dirt and lint. Clean these air inlet holes prior to each
heating season. Blocked air holes will create soot.
We recommend that you clean the unit every three
months during operation and have heater inspected
yearly by a qualified service person.
We also recommend that you keep the burner
tube and pilot assembly clean and free of dust and
dirt. To clean these parts we recommend using
compressed air no greater than 30 PSI (200 kPa).
Your local computer store, hardware store or home
center may carry compressed air in a can. You can
use a vacuum cleaner in the blow position. If using
compressed air in a can, please follow the direc-
tions on the can. If you don't follow directions on
the can, you could damage the pilot assembly.
1. Shut off the unit, including the pilot. Allow
the unit to cool for at least thirty minutes.
2. Inspect burner, pilot for dust and dirt.
3. Blow air through the ports/slots and holes in
the burner.
4. Never insert objects into the pilot tube.
Clean the pilot assembly also. A yellow tip on the
pilot flame indicates dust and dirt in the pilot as-
sembly. There is a small pilot air inlet about two
inches from where the pilot flame comes out of
the pilot assembly (see Figure 23). With the unit
off, lightly blow air through the air inlet. You may
blow through a drinking straw if compressed air
is not available.

CABINET

Air Passageways
Use a vacuum cleaner or pressurized air to
clean.
Exterior
Use a soft cloth dampened with a mild soap and
water mixture. Wipe the cabinet to remove dust.

BATTERIES

During long periods of time when the heater is
not being used, take batteries out of receiver and
ignitor. Remove exhausted batteries immediately.
Do not mix old and new batteries.
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burner will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low
You may feel your gas pressure is too low. If so, con-
tact your local natural or propane/LP gas supplier.
TECHNICAL SERVICE
You may have further questions about installation,
operation or troubleshooting. If so, contact DESA
Heating Productsʼ Technical Service Department
at 1-866-672-6040. When calling please have your
model and serial numbers of your heater ready.
You can also visit DESA Heating Productsʼ techni-
cal service web site at www.desatech.com.
Figure 23 - Pilot Air Inlet
Pilot Assembly
Pilot Air Inlet