INSTALLATION

Continued

WARNING: Never install the heater

in a bedroom or bathroom

in a recreational vehicle

where curtains, furniture, clothing or other flammable objects are less than 36 inches (91.4 cm) from the front or top of the heater or less than 10" (25.4 cm) from sides of heater

as a fireplace insert

in high traffic areas

in windy or drafty areas

CAUTION: If you install the heater in a home garage

heater pilot and burner must be at least 18 inches (45.7 cm) above floor

locate heater where moving vehicle will not hit it

CAUTION:Thisheatercreates warmaircurrents.Thesecurrents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operatingheaterwhereimpurities (such as, but not limited to, to- bacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, page 5. If high hu- midity is experienced, a dehumidifier may be used to help lower the water vapor content in the air.

For convenience and efficiency, install heater

where there is easy access for operation, inspec- tion and service

in coldest part of room

An optional fan kit is available from your dealer. See Accessories, page 22. If planning to use fan, locate heater near an electrical outlet.

INSTALLING REMOTE CONTROL RECEIVER

Remote control receiver must be installed to oper- ate the remote control.

1.Locate receiver bracket, two packages of AA batteries, remote receiver and screws in hardware bag included with your heater.

2.Remove battery cover on receiver and install batteries as shown in Figure 5. Replace battery cover.

3.Insert wire connector and wire through bush- ing on the back of heater (see Figure 6).

4.Lay heater onto its side. Insert wire connector into valve at location shown in Figure 7 page 9. Feed extra wire from receiver into heater base. Place heater back in upright position.

5.Attach bracket around receiver with screws as shown in Figure 6.

Receiver

AA Batteries

Battery Cover

Figure 5 - Installing Batteries in Receiver

Receiver

Receiver

Wire

Bushing

Connector

 

Bracket

 

 

 

Figure 6 - Installing Remote Receiver

8

www.desatech.com

113261-01A

Page 8
Image 8
Desa VTN25R, VTP22R, CTR22PR, CTR25NR Installing Remote Control Receiver, Receiver AA Batteries Battery Cover

CTR25NR, CTR22PR, VTN25R, VTP22R specifications

Desa VTN25R, VTP22R, CTR22PR, and CTR25NR are renowned models in the landscape of power generation and energy efficiency solutions. These products cater to varying needs, providing reliable performance for both residential and commercial applications.

The Desa VTN25R is distinguished by its robust design and high fuel efficiency, making it an ideal choice for users looking to balance power output with energy conservation. This model features a state-of-the-art EcoThrottle technology, which adjusts engine speed according to load, significantly reducing fuel consumption and noise levels. With a maximum output of 2500 watts, the VTN25R ensures that users can power a variety of appliances and equipment without concern for overloading.

Next in line, the Desa VTP22R model stands out for its versatility and compact form factor. Weighing in at just 45 pounds, this generator is incredibly portable, making it an excellent choice for outdoor enthusiasts and those needing backup power in emergency situations. It also incorporates a user-friendly digital display, allowing users to monitor fuel levels, output wattage, and engine performance at a glance. Its quiet operation and low emissions are additional highlights that make the VTP22R an environmentally conscious option.

Turning to the CTR22PR, this generator is designed with advanced inverter technology, supplying clean and stable power suitable for sensitive electronics. Its dual fuel capability allows it to run on both gasoline and propane, offering flexibility and convenience for users in diverse situations. The ergonomic handle and lightweight design facilitate easy transport, while the safety features, including overload protection and automatic shutoff, ensure peace of mind during operation.

Lastly, the CTR25NR model boasts higher wattage capacity coupled with enhanced durability. This unit features heavy-duty components, ensuring it can withstand rigorous usage over time. With features like an LED indicators panel and advanced cooling systems, the CTR25NR promises extended run times and operational efficiency. Users appreciate its ease of maintenance and serviceability, which translate into a longer lifespan.

In summary, the Desa VTN25R, VTP22R, CTR22PR, and CTR25NR generators offer a range of features and technologies tailored to meet the needs of different users. Whether it’s fuel efficiency, portability, clean power supply, or heavy-duty performance, these models demonstrate a commitment to reliability and innovation in the power generation market.