Figure 29 LOUVER REMOVAL
Figure 30 GLASS DOOR REMOVAL |
WARNING: The glass door must be securely in place before operating the fireplace. Do not operate the fireplace if glass is missing or broken.
BURNER FLAME ADJUSTMENT
The air shutter is located at the underside of the main burner (There are two (2) air shutters on the Propane gas versions). All have been factory preset to the proper
If readjustment is necessary, you can restore the proper air to gas ratio by loosening the air shutter screw and rotating the air shutter until the proper flame setting is achieved. (The air shutter’s normal setting is “fully opened”). Do not forget to retighten the air shutter screws (refer to figure 32).
Figure 31 | BURNER FLAME |
Figure 32 | VENTURI / ORIFICE CONNECTION |
BURNER REMOVAL
BEFORE PROCEEDING, MAKE SURE THE ENTIRE UNIT IS COOL.
1.Remove the top and bottom louvers. Open the glass door.
2.Carefully remove the log set and grate.
3.Remove the screws that attach the burner.
4.Slide the burner towards the front of the unit, lift, and remove from the firebox.
5.To reinstall the burner, slide the burner towards the rear of the unit and secure burner with screws. MAKE CERTAIN THE ORIFICE IS INSIDE THE VENTURI TUBE’S AIR SHUTTER.
6.Replace the log set and grate, close door with latches, and attach louvers.
- 11 - | For more information, visit www.desatech.com |