![FRAMING](/images/new-backgrounds/54828/5482813x1.webp)
Refer to the following table for clearance between roof and termination.
ROOF PITCH | MINIMUM HEIGHT ABOVE ROOF | |
| ft | mm |
FLAT - 7/12 | 1 | 305 |
7/12 - 8/12 | 1.5 | 457 |
8/12 - 9/12 | 2 | 610 |
9/12 - 10/12 | 2.5 | 762 |
10/12 - 11/12 | 4 | 1219 |
12/12 - 14/12 | 5 | 1524 |
14/12 - 16/12 | 6 | 1829 |
16/12 - 18/12 | 7 | 2134 |
18/12 - 20/12 | 7.5 | 2286 |
20/12 - 21/12 | 8 | 2438 |
FRAMING
Once the final location has been determined (observing clearances for vent termination), you may construct framing using dimensions shown in figures 10 through 12, depending on the particular installation.
Figure 10
Figure 11 |
If the appliance is to be installed directly on carpeting, tile (other than ceramic), or any combustible material other than wood flooring, the appliance must be installed upon a metal or wood panel extending the full width and depth of the fireplace.
24"
(61 cm) | 39 3/4" |
| |
| (101 cm) |
| MIN. |
43 1/4"
(110 cm)
Figure 12
ELECTRICAL HOOK-UP AND REMOTE RECEIVER DIAGRAM
A wire way with two receptacles has been supplied for your convenience and is located on the lower right hand side of the appliance (see figure 13).
Figure 13 | WIRE WAY |
Due to high temperatures, make sure no wires are touching the bottom of the firebox.
For more information, visit www.desatech.com |