Desa DVF34P Replacement Parts, Wiring Diagram, Service Hints, Technical Service

Models: DVF34P DVF34

1 36
Download 36 pages 59.87 Kb
Page 30
Image 30

DVF34, DVF34P

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized retailers of this product. If they can not supply original replacement part(s), call DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564).

When calling DESA International, have ready

your name

your address

model and serial numbers of your fireplace

how fireplace was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the defec- tive part to the factory.

WIRING DIAGRAM

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

Variable

Fan SwitchFan Switch

(N.O.)

Off 1

2

Black

 

On

 

Blue

110/115

V.A.C.

Black

Blower

 

White

Motor

Green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 55 - Blower Wiring Diagram for Thermostat-Controlled Models

PARTS NOT UNDER

WARRANTY

Contact authorized retailers of this product. If they can not supply original replacement part(s), call DESA International’s Parts Department at 1-800-972-7879 for referral information.

When calling DESA International, have ready

model number of your fireplace

the replacement part number

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

fireplace will not produce specified heat

propane/LP gas supply might be low (propane/LP units only)

When Gas Quality Is Bad

pilot will not stay lit

burners will produce flames and soot

fireplace will backfire when lit

If you feel your gas pressure is too low or gas quality is bad, contact your local natural or propane/LP gas supplier.

TECHNICAL

SERVICE

You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564).

You can also visit DESA International’s technical service web site at www.desatech.com.

30

106424

Page 30
Image 30
Desa DVF34P installation manual Replacement Parts, Wiring Diagram, Service Hints, Technical Service