Desa DVF34P Vertical Termination Configurations, Venting with Two 90 Elbow s

Models: DVF34P DVF34

1 36
Download 36 pages 59.87 Kb
Page 13
Image 13

OWNER’S MANUAL

VENTING INSTALLATION

Continued

3.Lower the support box through the hole in the roof until the bottom of the box extends at least 2" below the ceiling (see Figure 22). Align the support box vertically and horizontally using a level. Temporarily tack the support box in place through the inside walls and into the roof sheathing.

4.Using tin snips, cut the support box from the top corners down to the roofline and fold the resulting flaps over the roof sheathing (see Figure 23). Apply a bead of non-hardening mastic around the top edges of the support box to make a seal between the box and the roof. Nail in place with roofing nails. Remove any combustible material that might be in- side of the support box.

5.Complete the cathedral ceiling instal- lation by following the same proce- dures outlined in steps 2 through 7 for Flat Ceiling Installation, page 12.

Level

Cathedral ceiling support box

2" minimum below finished ceiling

Vertical Termination Configurations

Figures 24 through 27 show four different configurations for vertical termination. All connections must be sealed with high temperature silicone sealant as specified in the second warning statement on page 7.

 

Venting with Two 90° Elbows

 

Vertical (V)

Horizontal (H1) +

 

 

Horizontal (H2)

 

5' min.

2' max.

 

6' min.

4' max.

FD60

7' min.

6' max.

8' min.

8' max.

60˚ Starter/

 

 

Adapter Required

20' max.

8' max.

Note: Restrictor must be installed in all vertical installations.

Figure 24 - Vertical Rigid Venting Configuration Using Two 90° Elbows with Two

Horizontal Runs

Cut hole 1/8" larger than support box when projected onto roofline

Figure 22 - Cathedral Ceiling Support Box Installation

Non-hardening Mastic under all edges of support box before nailing

FD60

60˚ Starter/

Adapter

Required

Note: Restrictor must be installed in all vertical installations.

Venting with One 90° Elbow

Vertical (V)

Horizontal (H)

5' min.

2' max.

6' min.

4' max.

7' min.

6' max.

8' min.

8' max.

20' max.

8' max.

Figure 23 - Installed Cathedral Ceiling Support Box

Figure 25 - Vertical Rigid Venting Configuration Using One 90° Elbow

Continued

106424