INSTALLING OPTIONAL WIRELESS
NOTICE: Use only alkaline bat- teries (not included).
Installing Remote Receiver
1.Open bottom louver and locate the switch bracket on the left.
2.Unscrew the switch bracket. Lean bracket forward so you are able to ac- cess the back of the remote receiver.
3.Locate the battery clip mounted on the back of the receiver. Slide a
4.Attach the terminal wires to the battery.
5.Remove wire from TH to TPTH on control valve (see Figure 40).
6.Connect wires from receiver to TH and TPTH to control valve (see Figure 41).
7.Replace the switch bracket.
Receiver
Terminal
Wires
Battery Clip
Battery
Figure 39 - Attaching Alkaline Battery to Receiver
Figure 40 - Disconnecting TH to TPTH Wire
To
Optional
Remote
Accessory
Figure 41 - Control Valve Terminals
Installing
in
Unit
1.Remove battery cover on back of re- mote control unit.
2.Attach terminal wires to a
3.Replace battery cover onto remote con- trol unit.
Battery
Cover
Terminal | Remote |
Wires | Control Unit |
Battery
Housing
Figure 42 - Installing Alkaline Battery in Hand-Held Remote Control Unit
Remote
Control
Unit
Figure 43 - Installing Battery in Hand-Held
Remote Control Unit (GHRCTA Series
Only)
INSTALLING OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1
WARNING: Installation must be done by a qualified installer familiar with low voltage wiring procedures.
WARNING: Do not connect this thermostat to any electrical source! Electrical shock and/or fire hazard will occur.
NOTICE: The GWMT1 includes 25' of wire for installation. Your fire- place includes 15' of wire for ac- cessory installation. Choose the length that best fits your needs when installing this accessory.
1.Open lower louver panel. The valve is attached to the underside of the fire- box assembly.
2.Disconnect the wire that runs from TH to TPTH from the valve as shown in Figure 40.
3.Connect one terminal of the provided wire for the wall thermostat to the TPTH terminal on the valve. Connect remain- ing wire terminal to the TH terminal on the valve. Make sure that the wire termi- nals are in the positions on the unit as pictured in Figure 44. If wires are not connected as shown the thermostat will not work.
To Wall Optional
Remote Accessory
t
Figure 44 - Control Valve Terminals
Continued