OWNER’S MANUAL

FIREPLACE INSTALLATION

Continued

INSTALLING OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL - GHRC SERIES/GHRCT SERIES

NOTICE: Use only alkaline bat- teries (not included).

Installing Remote Receiver

1.Open bottom louver and locate the switch bracket on the left.

2.Unscrew the switch bracket. Lean bracket forward so you are able to ac- cess the back of the remote receiver.

3.Locate the battery clip mounted on the back of the receiver. Slide a 9-volt al- kaline battery (not included) through the clip (see Figure 39).

4.Attach the terminal wires to the battery.

5.Remove wire from TH to TPTH on control valve (see Figure 40).

6.Connect wires from receiver to TH and TPTH to control valve (see Figure 41).

7.Replace the switch bracket.

Receiver

Terminal

Wires

Battery Clip

9-Volt Alkaline

Battery

Figure 39 - Attaching Alkaline Battery to Receiver

Figure 40 - Disconnecting TH to TPTH Wire

To

Optional

Remote

Accessory

Figure 41 - Control Valve Terminals

Installing 9-Volt Alkaline Battery

in Hand-Held Remote Control

Unit

1.Remove battery cover on back of re- mote control unit.

2.Attach terminal wires to a 9-volt alka- line battery (not included). Place bat- tery into the battery housing.

3.Replace battery cover onto remote con- trol unit.

Battery

Cover

Terminal

Remote

Wires

Control Unit

9-Volt Alkaline Battery

Battery

Housing

Figure 42 - Installing Alkaline Battery in Hand-Held Remote Control Unit

Remote

Control

Unit

Figure 43 - Installing Battery in Hand-Held

Remote Control Unit (GHRCTA Series

Only)

INSTALLING OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1

WARNING: Installation must be done by a qualified installer familiar with low voltage wiring procedures.

WARNING: Do not connect this thermostat to any electrical source! Electrical shock and/or fire hazard will occur.

NOTICE: The GWMT1 includes 25' of wire for installation. Your fire- place includes 15' of wire for ac- cessory installation. Choose the length that best fits your needs when installing this accessory.

1.Open lower louver panel. The valve is attached to the underside of the fire- box assembly.

2.Disconnect the wire that runs from TH to TPTH from the valve as shown in Figure 40.

3.Connect one terminal of the provided wire for the wall thermostat to the TPTH terminal on the valve. Connect remain- ing wire terminal to the TH terminal on the valve. Make sure that the wire termi- nals are in the positions on the unit as pictured in Figure 44. If wires are not connected as shown the thermostat will not work.

To Wall Optional

Remote Accessory

t

Figure 44 - Control Valve Terminals

Continued

106394

21

Page 21
Image 21
Desa DVFH34P installation manual Installing Optional Wall Mounted Thermostat GWMT1, Installing Remote Receiver