BLUE FLAME NATURAL GAS HEATER
INSTALLATION
Continued
CONNECTING TO GAS SUPPLY
WARNING: This appliance re- quires a 3/8" NPT (National Pipe Thread) inlet connection to the pressure regulator.
WARNING: A qualified service person must connect heater to gas supply. Follow all local codes.
Typical Inlet Pipe Diameters
FGHS30NG | 1/2" or greater |
Installation must include an equipment shutoff valve,union,andplugged1/8"NPTtap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 13).
IMPORTANT: Install an equipment shutoff valve in an accessible location. The equip- ment shutoff valve is for turning on or shutting off the gas to the appliance.
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
CAUTION: Use pipe joint seal- ant that is resistant to natural gas.
Install sediment trap in supply line as shown in Figure 13. Locate sediment trap where it is within reach for cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater con- trols. If sediment trap is not installed or is installed wrong, heater may not run properly.
IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/or fittings.
WARNING: Never connect heater to private
IMPORTANT: Check gas line pressure be- fore connecting heater to gas line. Gas line pressure must be no greater than 14 inches of water. If gas line pressure is higher, heater regulator damage could occur.
CAUTION: Use only new, black iron or steel pipe. Inter-
| 3/8" NPT |
| |||||
| Pipe Nipple |
| |||||
|
|
|
|
|
|
|
|
|
|
| Tee Joint | ||||
Test | Reducer | ||||||
Gauge | Bushing to | ||||||
Connection * |
|
| 1/8" NPT | ||||
|
| ||||||
|
|
| 1/8" NPT | ||||
|
|
| Plug Tap | ||||
|
|
|
|
|
|
| Tee |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| Joint |
Sediment |
|
| Pipe | ||||
|
| ||||||
Trap |
|
|
|
| Nipple | ||
|
|
|
|
|
|
| Cap |
Figure 13 - Gas Connection
Pressure
Regulator
Heater
Cabinet
Ground Joint Union
Equipment
Shutoff
Valve *
Typical Inlet Pipe from Gas Meter (4" W.C. to 10.5" W.C. Pressure)
3" Minimum
*A CSA
10 | 107340 |