BLUE FLAME NATURAL GAS HEATER

AIR FOR COMBUSTION AND VENTILATION

WARNING: This heater shall not be installed in a confined space or unusually tight con- struction unless provisions are provided for adequate combus- tion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.

Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper com- bustion and ventilation.

Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide ad- equate fresh air for these appliances. This will insure proper venting of vented fuel- burning appliances.

PROVIDING ADEQUATE VENTILATION

The following are excerpts from National Fuel Gas Code, NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation.

All spaces in homes fall into one of the three following ventilation classifications:

1.Unusually Tight Construction

2.Unconfined Space

3.Confined Space

The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.

Unusually Tight Construction

The air that leaks around doors and win- dows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

Unusually tight construction is de- fined as construction where:

a.walls and ceilings exposed to the outside atmosphere have a con- tinuous water vapor retarder with a rating of (one perm 6x10-11kg per pa-sec-m2) or less with open- ings gasketed or sealed and

b.weather stripping has been added on openable windows and doors and

c.caulking or sealants are applied to areas such as joints around window and door frames, be- tween sole plates and floors, be- tween wall-ceiling joints, be- tween wall panels, at penetra- tions for plumbing, electrical, and gas lines, and at other openings.

If your home meets all of the three criteria above, you must provide ad- ditional fresh air. See Ventilation Air From Outdoors, page 6.

If your home does not meet all of the three criteria above, proceed to De- termining Fresh-Air Flow For Heater Location, page 5.

Confined and Unconfined Space

The National Fuel Gas Code, ANS Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggre- gate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are con- sidered a part of the unconfined space.

This heater shall not be installed in a con- fined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.

*Adjoining rooms are communicating only if there are doorless passageways or ventila- tion grills between them.

4

107340

Page 4
Image 4
Desa FGHS30NGB AIR for Combustion and Ventilation, Providing Adequate Ventilation, Unusually Tight Construction

FGHS30NGB specifications

The Desa FGHS30NGB is a leading model in the world of portable propane gas heaters, widely renowned for its exceptional performance, advanced features, and versatile applications. Designed to provide efficient heating, this model delivers warmth where it is needed most, perfect for both indoor and outdoor environments.

One of the standout features of the FGHS30NGB is its powerful heating capability, boasting an output of 30,000 BTUs. This makes it ideal for quickly warming up large spaces, whether that be a workshop, garage, or patio. The unit is designed with an adjustable heat setting, allowing users to customize their heating preferences according to their specific needs.

Another significant aspect of the FGHS30NGB is its safety features. The unit is equipped with a built-in automatic shut-off system that activates when the heater is tipped over or does not detect oxygen, ensuring peace of mind during usage. Additionally, the unit is designed with a sturdy and durable construction, making it suitable for outdoor use as well.

The FGHS30NGB incorporates modern technologies that enhance its efficiency. It features an innovative combustion system that allows for optimal fuel utilization, minimizing emissions and maximizing heat output. This not only makes it environmentally friendly but also economical for users, as they can expect reduced operational costs.

Portability is a key characteristic of the FGHS30NGB. It comes with a convenient handle and lightweight design, making it easy to transport from one location to another. Whether you're heading to a construction site or enjoying a weekend camping trip, this portable heater provides the flexibility needed for various situations.

In terms of design, the FGHS30NGB is both functional and aesthetically pleasing. Its compact size ensures it fits comfortably in tight spaces, while its modern look allows it to blend seamlessly with different decor styles.

In summary, the Desa FGHS30NGB propane heater is an excellent choice for anyone seeking reliable, efficient, and portable heating solutions. Its powerful performance, advanced safety features, and user-friendly design make it a top contender in today’s market, offering unmatched versatility for an array of heating needs.