OPERATING FIREPLACE

Continued

Figure 26 - Pilot

TO TURN OFF GAS

TO APPLIANCE

1.Turn off all electric power to the appliance if service is to be performed.

2.Remove control access panel.

3.Close the gas valve.

CLEANING AND

MAINTENANCE

WARNING: Installation and repair should be done by a quali- fied service person. The appli- ance should be inspected before each use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding mate- rial, pet hair, etc. It is imperative that the control compartments, burners and circulating air sys- tem be kept clean.

WARNING: The logs can be hot. Handle only when cool.

WARNING: Turn off gas and electrical power before servicing appliance. Any safety screen or guard removed for servicing must be replaced prior to operat- ing the appliance.

WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage.

Keep control compartment, logs, burner and area surrounding logs clean by vacuuming or brushing at least twice a year. Take care not to alter the set- tings on the pilot assembly.

Do not use abrasive liquids or cleaners for cleaning glass doors and trims. Any household glass cleaner should suffice. Do not clean doors when hot. Allow appliance to cool before cleaning.

TECHNICAL SERVICE

You may have further questions about installation, operation or troubleshooting. If so, contact DESAʼs Technical Service Department at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready.

You can also visit DESAʼs Technical Services web site at www.desatech.com.

SPECIFICATIONS

GL36PN, GL36PNE

Maximum Input Rating at Altitudes: 2,000 ft. - 42,000 Btu/hr., 2,000 ft. to 4,000 ft. - 37,800 Btu/hr.

Manifold Pressure: 3.5 W.C. (.87 kPa)

Supply Pressure (in. of water): Minimum* - 4.5" (1.12 kPa), Maximum - 11.0" (2.74 kPa)

Orifice Size at Altitudes: 2,000 ft. - #30, 2,000 ft. to 4,000 ft. - #31

* For the purpose of input adjustment

GL36PNP, GL36PNEP

Maximum Input Rating at Altitudes: 2,000 ft. - 42,000 Btu/hr., 2,000 ft. to 4,000 ft. - 37,800 Btu/hr.

Manifold Pressure: 11.0 W.C. (2.74 kPa)

Supply Pressure (in. of water): Minimum* - 12.0" (2.89 kPa), Maximum - 13.0" (3.23 kPa)

Orifice Size at Altitudes: 2,000 ft. - #49, 2,000 ft. to 4,000 ft. - #51

* For the purpose of input adjustment

55175-F

www.desatech.com

15

Page 15
Image 15
Desa GL36PNEP, GL36PNP installation manual Cleaning Maintenance, Technical Service, Specifications

GL36PNEP, GL36PNP, GL36PN, GL36PNE specifications

Desa GL36PN, GL36PNP, GL36PNEP, and GL36PNE are advanced gas fireplaces designed to provide warmth, ambiance, and aesthetic appeal to any living space. These models are known for their cutting-edge features and efficient technology, making them ideal for modern homes looking for both comfort and style.

One of the main features of the Desa GL series is its versatile design, allowing it to seamlessly integrate into various interior styles. The clean and elegant lines of the fireplaces make them an attractive focal point in any room, whether traditional or contemporary. The models come with different finishing options, including a range of trims and decorative fronts, allowing homeowners to customize their look according to personal preference and home decor.

Another significant characteristic of these models is their innovative heating technology. The Desa GL series utilizes advanced venting options that enhance heat distribution throughout the space while ensuring optimal safety. With a focus on efficiency, these appliances are designed to heat effectively while consuming minimal gas, helping homeowners save on energy costs. The models are equipped with an electronic ignition system that ensures reliable lighting and consistent performance, even during power outages.

In addition to heating performance, the Desa GL36PN, GL36PNP, GL36PNEP, and GL36PNE prioritize user comfort and convenience. The included remote control allows for easy adjustments to flame height and temperature, enabling homeowners to create their desired atmosphere with just the push of a button. Some models also come with programmable thermostats, further enhancing user experience by allowing automatic temperature regulation throughout the day.

Safety features are paramount in the design of the Desa GL series. Each model is equipped with a safety shut-off system, ensuring peace of mind for users. The glass front is designed to remain cool to the touch, preventing accidental burns, which is especially important for families with children or pets.

Finally, the aesthetic appeal of the Desa GL series is further enhanced by the realistic flame display and high-quality log sets. The lifelike flame appearance creates a captivating ambiance, making the fireplace a centerpiece in any room, perfect for gatherings or cozy nights in.

In conclusion, the Desa GL36PN, GL36PNP, GL36PNEP, and GL36PNE models combine modern aesthetics with advanced features, ensuring both comfort and safety in home heating. With efficient technology and customizable designs, these fireplaces are a perfect addition to any contemporary living space, offering warmth, style, and convenience.