INTRODUCTION

INTRODUCTION

Models GL36PN/P and GL36PNE/P are decora- tive gas appliances that use a millivolt gas control and piezo pilot or an electronic gas control valve with an electronic ignition system respectively. These systems require a 6", B-type venting system for operation.

The 6" B-type vent is not supplied by DESA. For installation guidelines, check your B-vent instructions.

BEFORE YOU BEGIN WARNING: This gas appli- ance must not be connected to a chimney flue servicing a solid fuel burning appliance.

Models GL36PN and GL36PNE are smooth face units for natural gas only. The GL36PNP and GL36PNEP are smooth face units for propane/LP gas only. To determine which type of gas your unit is approved and tested for, check the rating plate on the lift-out plate located inside the firebox under the access panel.

BEFORE YOU BEGIN

Before beginning the installation of your appli- ance, read these instructions through completely.

This DESA appliance and its approved compo- nents are safe when installed according to this installation manual and are operated as recom- mended by DESA. Unless you use DESA approved components tested for this appliance, YOU MAY

CAUSE A FIRE HAZARD!

The DESA warranty will be voided by and DESA dis- claims any responsibility for the following actions :

A)Modification of the appliance or any of the components manufactured by DESA unless otherwise permitted by DESA.

B)Use of any component part not approved by DESA in combination with this appliance.

C)Installation and/or operation in a manner other than instructed in this manual.

D)The burning of anything other than the type of gas approved for use in this gas appliance.

This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electri- cal Code, ANSI/NFPA 70-1987and the CSA C22.1 Canadian Electrical Code for Canada.

The installation must conform with local codes or, in the absence of local codes, with the current National Fuel Gas Code, ANSI Z223.1/NFPA 54 or with the current CAN/CGA B149 Installation Codes for Canada.

This appliance complies with ANSI Z21.50B-1990and CAM/CGA-2.22-M89as a Vented Gas Ap- pliance and is listed and tested by the Omni Test Laboratories.

SELECTING LOCATION WARNING: Installation of this appliance should be done by a qualified service person well trained in the installation of such appliances. You will also need a building permit from your local BuildingandSafetyCommissioner before installing this appliance; otherwise your insurance compa- ny may not cover this appliance.

NOTICE: This appliance is not intended to be used as a primary source of heat.

SELECTING LOCATION

To determine the safest and most efficient location for your appliance, you must take into consider- ation the following guidelines:

1.The location must allow for proper clearances (see Clearances, page 6). Note: This decora- tive appliance is not designed for outdoor installation.

2.The location should be in a place where drafts, air conditioning ducts, windows or doors will not affect fireplace heat output.

3.A location that avoids the cutting of joists or roof rafters will make installation easier. Figure 2 shows a typical three-sided fireplace installation.

IMPORTANT: Side openings must be located at least 3 feet from facing wall or combustible mate- rial. End opening must be located at least 1 foot from facing wall or combustible material.

Existing

Side

Wall

4" From Opening to

Perpendicular Wall Access Control Panel

Figure 2 - Typical Two-Sided Fireplace

Installation