Desa GL36PNP Fireplace Installation, WARNING Gas line hookup, should be done by your gas, person

Models: GL36PNEP GL36PNP GL36PN GL36PNE

1 20
Download 20 pages 39.9 Kb
Page 9
Image 9
GAS SUPPLY TESTING

FIREPLACE

INSTALLATION

Continued

The gas control valve is secured to the burner pan assembly underneath the front ledge. A 1/8" NPT plugged tapping is provided on the gas control valve for a test gauge connection immediately upstream of the gas supply connection to the ap- pliance (see Figures 13 and 14).

Strain Relief

Grommet

ON/OFF Knob GAS LINE HOOK-UP

 

Pilot Gas Line

Pilot

Do Not Kink

To Pilot

 

Adjustment

Burner

Cap

 

 

 

 

To Main

 

 

Burner

Common

Ground Wire

Figure 12 - Wiring Through Outer Surround

GAS SUPPLY TESTING

Note: This section is intended as a guide for quali- fied technicians installing gas to this appliance.

WARNING: Gas line hookup CAUTION: Do not connect appliance before pressure test- ing gas piping. Damage to gas valve may result and an unsafe condition may be caused.

The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).

The appliance must be isolated from the gas sup- ply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

This unit has been tested for installation at high altitude in accordance with Canadian test stan- dard CAN/CGA-2.17. Higher altitudes affect the atmospheric pressure and heat valve of gaseous fuels. When installing this unit at high altitudes, the rated input will be lower than at sea level. The lowered oxygen content in the air and the lowered gas density require installation of a different size orifice in order to achieve clean combustion of the unit. Consult the unit data plate for the proper high-altitude orifice size. Fill out the information sticker attached to the unit when field converting. See Specifications, page 15, when derating.

Inlet

 

Outlet

 

Pressure Pressure

 

 

Figure 13 - Millivolt Control Valve

 

 

 

To

 

 

 

Main

 

 

 

Burner

From

 

 

Gas

 

E

A

Supply

Inlet

Outlet

Pressure

 

 

 

 

Pressure

 

 

 

Figure 14 - Electronic Control Valve

GAS LINE HOOK-UP

 

WARNING: Gas line hookup

should be done by your gas

supplier or a qualified service

person.

 

 

WARNING: Before you pro-

ceed, make sure your gas supply

is OFF.

 

A manual shutoff valve has been included in the

applianceʼs gas supply system. You may consider

installing an extra gas shutoff valve outside the ap-

plianceʼs enclosure (check with local codes) where

it can be accessed more conveniently with a key

through a wall as shown in Figure 15, page 10.

A 30" long, 1/2" NPT SCHD 40 flexible gas line

(supplied) may be used between the incoming 1/2"

NPT black iron gas line and the fireplace regulator

(located inside the firebox, under the access plate).

The incoming gas line may be routed toward the

appliance from either the left or right hand side of

fireplace outer surround.

55175-F

www.desatech.com

9

Page 9
Image 9
Desa GL36PNP Fireplace Installation, WARNING Gas line hookup, should be done by your gas, supplier or a qualified service