Desa GVC35NA, GVC50NA, GVC65NA Service Procedures, Removing Control Valve and Burner Tube

Models: GVC35NA GVC50NA GVC65NA

1 36
Download 36 pages 36.79 Kb
Page 28
Image 28
SERVICE PROCEDURES

SERVICE PROCEDURES

Removing Control Valve and Burner Tube

1.Shut off gas supply to heater.

2.Remove lower front access panel on heater.

3.Disconnect burner tube from orifice holder (see Figure 18).

4.Remove pilot gas line from control valve (see Figure 18).

5.Disconnect wire connec- tors from thermocouple interrupter (see Figure 18).

6.Remove thermocouple and thermocouple inter- rupter from control valve.

7.Remove cotter pin from control valve. This releases the control rod from valve (see Figure 18).

8.Remove the two mounting screws from control valve mounting bracket (see Figure 18).

9.Remove assembly from the rear of heater. Pull burner tube through hole in combustion chamber.

10.To reinstall, reverse above steps. Turn on gas to heater and check for gas leaks. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

11.Replace lower front access panel.

28

Removing Control Valve and Burner Tube WARNING

Turn off and unplug heater and let cool before servicing. Unless you need gas supply for testing, shut off manual shutoff valve before servicing. Only a qualified service person should service and repair heater and venting system.

Control Rod

Cotter Pin

Control Valve

Control Valve

Bracket

 

 

Mounting

Orifice

Screw

Holder

 

Burner Tube

Wire Connector

Thermocouple

 

Interrupter

 

Thermocouple

 

 

Pilot Gas Line

 

Wire Connector

Figure 18 - Removing Control Valve and Burner Tube