Desa GWN20TA, GWP20TA, WMP20A Troubleshooting, Continued, Observed Problem, Possible Cause, Remedy

Models: WMN20A WMP20A GWN30TA GWP20TA GWN20TA GWP30TA

1 28
Download 28 pages 40.9 Kb
Page 21
Image 21
Maintenance, page 18)

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

Yellow flame during burner

1.

Not enough air

1.

Check burner for dirt and

combustion

 

 

 

debris. If found, clean

 

 

 

 

burner (see Cleaning and

 

 

 

 

Maintenance, page 18)

 

2.

Gas regulator defective

2.

Replace gas regulator

 

3.

Clogged or dirty burner

3.

Clean burner (see Cleaning

 

 

 

 

and Maintenance, page 18)

 

 

 

 

 

Slight smoke or odor during

1.

Residues from manufactur-

1.

Problem will stop after a few

initial operation

 

ing processes

 

hours of operation

 

 

 

 

 

Heater produces a whistling

1.

Turning control knob to 5

1.

Turn control knob to 1 posi-

noise when burner is lit

 

position when burner is

 

tion and let warm up for a

 

 

cold

 

minute

 

2.

Air in gas line

2.

Operate burner until air is

 

 

 

 

removed from line. Have

 

 

 

 

gas line checked by local

 

 

 

 

natural or propane/LP gas

 

 

 

 

company

 

3.

Air passageways on heater

3.

Observe minimum installa-

 

 

blocked

 

tion clearances (see Figure

 

 

 

 

4, page 8)

 

4.

Dirty or partially clogged

4.

Clean burner (see Cleaning

 

 

burner orifice

 

and Maintenance, page 18)

 

 

 

 

or replace burner orifice

 

 

 

 

 

White powder residue forming

1.

When heated, vapors from

1.

Turn heater off when us-

within burner box or on adja-

 

furniture polish, wax, carpet

 

ing furniture polish, wax,

cent walls or furniture

 

cleaners, etc. may turn into

 

carpet cleaners or similar

 

 

white powder residue

 

products

 

 

 

 

 

Heater produces a clicking/

1.

Metal expanding while heat-

1.

This is normal with most

ticking noise just after burner

 

ing or contracting while

 

heaters. If noise is exces-

is lit or shut off

 

cooling

 

sive, contact qualified ser-

 

 

 

 

vice person

119344-01B

www.desatech.com

21

Page 21
Image 21
Desa GWN20TA, GWP20TA, GWP30TA Troubleshooting, Continued, Observed Problem, Possible Cause, Remedy, Maintenance, page