Troubleshooting
WARNING:Turnoffandunplugheaterandletcoolbeforeservicing. Only a qualified service person should service and repair heater.
CAUTION: Never use a wire, needle or similar object to clean ODS/pilot. This can damage ODS/pilot unit.
Note: All troubleshooting items are listed in order of operation.
OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY | ||
|
|
|
| |
When ignitor button is pressed, | 1. Ignitor electrode positioned | 1. | Replace pilot assembly | |
there is no spark at ODS/ |
| wrong |
|
|
pilot | 2. Ignitor electrode broken | 2. | Replace pilot assembly | |
| 3. | Ignitor electrode not con- | 3. | Reconnect ignitor cable |
|
| nected to ignitor cable |
|
|
| 4. | Ignitor cable pinched or | 4. | Free ignitor cable if pinched |
|
| wet |
| by any metal or tubing. |
|
|
|
| Keep ignitor cable dry |
| 5. | Broken ignitor cable | 5. | Replace ignitor cable |
| 6. | Bad piezo ignitor | 6. | Replace piezo ignitor |
|
|
|
| |
When ignitor button is pressed, | 1. Gas supply turned off or | 1. | Turn on gas supply or open | |
there is spark at ODS/pilot but |
| equipment shutoff valve |
| equipment shutoff valve |
no ignition |
| closed |
|
|
| 2. | Control knob not in PILOT | 2. | Turn control knob to PILOT |
|
| position |
| position |
| 3. | Control knob not pressed in | 3. | Press in control knob while |
|
| while in PILOT position |
| in PILOT position |
| 4. | Air in gas lines when in- | 4. | Continue holding down |
|
| stalled |
| control knob. Repeat ignit- |
|
|
|
| ing operation until air is |
|
|
|
| removed |
| 5. | Depleted gas supply (pro- | 5. | Contact local propane/LP |
|
| pane/LP gas only) |
| gas company |
| 6. | ODS/pilot is clogged | 6. | Clean ODS/pilot (see Clean- |
|
|
|
| ing and Maintenance, page |
|
|
|
| 18) or replace ODS/pilot |
|
|
|
| assembly |
| 7. | Gas regulator setting is not | 7. | Replace gas regulator |
|
| correct |
|
|
www.desatech.com | 19 |