TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning sup- plies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

Heater produces unwanted

1.

Heater burning vapors from

1.

Ventilate room. Stop us-

odors

 

paint, hair spray, glues, etc.

 

ing odor causing products

 

 

(see IMPORTANT state-

 

while heater is running

 

 

ment above)

 

 

 

2.

Low fuel supply (propane/

2.

Refill supply tank

 

 

LP gas only)

3.

Locate and correct all leaks

 

3.

Gas leak. See Warning

 

(see Checking Gas Con-

 

 

statement above

 

nections, page 13)

 

 

 

 

 

Heater shuts off in use (ODS

1.

Not enough fresh air is

1.

Open window and/or door

operates)

 

available

 

for ventilation

 

2.

Low line pressure

2.

Contact local natural or

 

 

 

 

propane/LP gas company

 

3.

ODS/pilot is partially

3.

Clean ODS/pilot (see Cleaning

 

 

clogged

 

and Maintenance, page 18)

 

 

 

 

 

Gas odor even when control

1.

Gas leak. See Warning

1.

Locate and correct all leaks

knob is in OFF position

 

statement above

 

(see Checking Gas Con-

 

 

 

 

nections, page 13)

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

Gas odor during combustion

1.

Foreign matter between

1.

Take apart gas tubing and

 

 

control valve and burner

 

remove foreign matter

 

2.

Gas leak. See Warning

2.

Locate and correct all leaks

 

 

statement above

 

(see Checking Gas Con-

 

 

 

 

nections, page 13)

 

 

 

 

 

Moisture/condensation no-

1.

Not enough combustion/

1.

Refer to Air for Combustion

ticed on windows

 

ventilation air

 

and Ventilation require-

 

 

 

 

ments (page 5)