Desa WMP20A Operating Heater, Continued, To Turn Off Gas To Appliance, Manual Lighting Procedure

Models: WMN20A WMP20A GWN30TA GWP20TA GWN20TA GWP30TA

1 28
Download 28 pages 40.9 Kb
Page 16
Image 16
OPERATING HEATER

OPERATING HEATER

Continued

Figure 21 - Pilot (actual pilot may vary) WARNING: Always operate manual control heaters at the locked positions. Operation between these positions may create a possible health hazard if used in a poorly ventilated room. Read owner’s manual for complete instructions.

TO TURN OFF GAS CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

Thermocouple

Shutting Off Heater Ignitor Electrode

Shutting Off Burner Only (pilot stays lit)THERMOSTAT CONTROL Pilot Burner

Figure 21 - Pilot (actual pilot may vary)

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise MANUAL LIGHTING to the OFF position.

2.Turn off all electric power to the appliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise Manual background to the PILOT position.

THERMOSTAT CONTROL

OPERATION

The thermostatic control used on these models differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room temperature. The thermostat adjusts the amount of gas flow to the burner. This increases or decreases the burner flame height. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any heat level between 1 and 5. Selecting the 5 setting will cause the burner to remain fully on without modulating down in most cases.

Note: The thermostat sensing bulb mea- sures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, installation location, room size, open air temperatures, etc.). Frequent use of your heater will let you determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1.Remove front panel (see Figure 7, page 9).

2.Follow steps 1 through 7 under Lighting Instructions, page 15.

3.With control knob pressed in, strike match. Hold match to pilot until pilot lights.

4.Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob. Now follow step 9, under Lighting Instructions, page 15.

5.Replace front panel.

16

www.desatech.com

119344-01B

Page 16
Image 16
Desa WMP20A Operating Heater, Continued, To Turn Off Gas To Appliance, Thermostat Control Operation, Shutting Off Heater