COMBUSTION AIR KIT MODEL AK4 (OPTIONAL)

INSTALLATION

Combustion Air Kit Model AK4 (Optional)

Appliance Enclosure

Installing Optional Glass Door Accessory

15

INSTALLATION

Continued

COMBUSTION AIR KIT MODEL AK4 (OPTIONAL)

The outside air kit may be installed on the left side of the fireplace only. The vent can be installed through the outside wall or a ventilated crawl space. The handle to operate the damper door for the outside air inlet will be located inside the left “screen pocket” of the firebox (see Figure 31). Pull the handle to open or push to close.

APPLIANCE ENCLOSURE CAUTION: Air inlet ducts are not to terminate in attic space.

Screen Pocket

Air Kit

Handle

Figure 31 - Air Kit Handle Location

APPLIANCE ENCLOSURE

Before finishing the enclosure around the appliance, inspect all joints around the outer surround. Any gaps between the nailing flanges and the framing should be sealed with noncombustible insulation or caulking.

If the appliance is mounted on a raised platform, it must be a continuous surface and not on blocks without a solid surface. This will prevent the entry of cold air by means of conduction through the total bottom of the appliance. (see Figure 32).

INSTALLING OPTIONAL GLASS DOOR ACCESSORY

INSTALLING OPTIONAL GLASS DOOR ACCESSORY CAUTION: Use only glass doors certified for use with this appliance.

Note: Glass door may be heavy for some individuals. If this is the case, please request help from someone else.

The M36E, VM36E, M42E and VM42E B-vent fireplaces are approved for use with optional bi-fold glass doors (see Accessories, page 25). The glass panels may be ordered and installed anytime after the fireplace installation is complete.

Follow these steps to install left and right panels:

1.With the handle at the bottom, completely fold the panel on its hinges.

2.With the handle facing the center of the firebox opening, in- sert the lower pivot pin on the glass door panel into the hole in pivot plate on the bottom edge of the fireplace opening (see Figure 33).

3.Keeping the folded door tilted, slide the upper two pins into the guide track found under the upper facial edge of the fire- box opening.

4.Tilt the glass assembly fully vertical until the outer pivot pin snaps into the mounting hole in the upper spring clip (see Figure 33).

Slide Top PinSpring Clip

Into Door Track

Insert Pin Into

Spring Clip

Side

Side

 

Framing

Framing

Insert Bottom

 

 

 

 

Pivot Pin Into

 

 

Pivot Plate and

 

 

Swing Door Into

 

 

Vertical Position

Caulk Here

Pack Insulation

Pivot Plate

Figure 32 - Sealing Between Appliance and Framing

Figure 33 - Installing Optional Glass Door

Manual backgroundManual backgroundManual backgroundManual backgroundFor more information, visit www.desatech.com

108796-01D

Page 15
Image 15
Desa M36E, M42E, VM36E, VM42E COMBUSTION AIR KIT MODEL AK4 OPTIONAL, Appliance Enclosure, Installation, Continued

FAQ

What is the location for the air kit handle?

The handle to operate the damper door for the outside air inlet is located inside the left screen pocket of the firebox. Refer to Figure 31 for the exact location.

Can I install optional glass doors for my fireplace?

Yes, the M36E, VM36E, M42E, and VM42E B-vent fireplaces are approved for use with optional bi-fold glass doors. Follow the steps in the article to install the glass doors. For more information, visit www.desatech.com108796-01D

What should I do before finishing the enclosure around the appliance?

Before finishing the enclosure, inspect all joints around the outer surround. Seal any gaps between the nailing flanges and the framing with noncombustible insulation or caulking. Ensure that the appliance is mounted on a continuous surface to prevent the entry of cold air.