TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

Yellow flame during burner

1.

Not enough air

1.

Check burner for dirt and

combustion

 

 

 

debris. If found, clean burner

 

 

 

 

(see Cleaning and Mainte-

 

2.

Gas regulator defective

 

nance, page 22)

 

2.

Replace gas regulator

 

 

 

 

 

Slight smoke or odor during initial

1.

Residues from manufacturing

1.

Problem will stop after a few

operation

 

processes

 

hours of operation

 

 

 

 

 

Fireplace produces a whistling

1.

Turning control knob to HI

1.

Turn control knob to LO

noise when burner is lit

 

position when burner is cold

 

position and let warm up for

 

2.

Air in gas line

 

a minute

 

2.

Operate burner until air is

 

 

 

 

removed from line. Have gas

 

3.

Air passageways on fireplace

 

line checked by local propane/

 

 

LP gas company

 

 

blocked

3.

Observe minimum installation

 

4.

Dirty or partially clogged

 

clearances (see Figures 7 and

 

 

8, page 9)

 

 

burner orifice

4.

Clean burner (see Cleaning

 

 

 

 

and Maintenance, page 22)

 

 

 

 

or replace burner orifice

 

 

 

 

 

White powder residue forming

1.

When heated, vapors from

1.

Turn heater off when using

within burner box or on adjacent

 

furniture polish, wax, carpet

 

furniture polish, wax, carpet

walls or furniture

 

cleaners, etc. may turn into

 

cleaners, or similar products

 

 

white powder residue

 

 