Arrestor Cleaning
screws. Verify that both the left and right side inner doors are properly positioned and sealed against the combustion chamber.
Step 8.
Step 9. To resume operation, follow the instructions located on the water heater lighting instruction label. Or, use the lighting instructions located in the water heater installation and operating manual.
ScreenLok® Flame Arrestor Cleaning Procedure
Step 1. Move the gas control power switch to the “OFF” position and unplug the water heater from the wall outlet.
Step 2. Remove the outer door.
Step 3. Remove the right side inner door per the Inner Door Removal Procedure on page 32.
Step 4. Disconnect the pilot tube using a 7/16” wrench and the main burner feedline with a 3/4” wrench from the gas control.
Step 5. Disconnect the spark igniter/flame sensor wire from gas control.
Step 6. Remove the burner assembly from the combustion chamber.
Step 7. Clean the ScreenLok® flame arrestor using a stiff brush, compressed air, and/or a shop vacuum to remove any scale or other debris accumulation. Using a soft brush, clear jacket openings from any dirt, dust, restrictions, or other obstructions.
Step 8. Remove any debris from the burner assembly following the Burner Cleaning Procedure on page 15.
Step 9.
Step 10. Reconnect the main and pilot tubing and spark igniter wire to the gas control.
Step 11.
Step 12. To resume operation, follow the instructions located on the water heater lighting instruction label. Or, use the lighting instructions located in the water heater installation and operating manual.
Page 49
49