Bradford-White Corp U4TW50T*FRN, U4TW40T*FRN, U4TW60T*FRN Safety Circuit Voltage Trace, Page

Models: U4TW60T*FRN U4TW40T*FRN U4TW50T*FRN

1 52
Download 52 pages 25.44 Kb
Page 42
Image 42
Safety Circuit Voltage Trace
Control access
cover

Safety Circuit Voltage Trace

Manual backgroundWARNING

115 volt potential exposure. Use caution making voltage checks to avoid

personal injury.

Safety Circuit Voltage Trace

14

Note: This procedure assumes a cold tank.

Step 1. Remove three screws (Phillips screw driver) from control access cover on blower and remove

cover.

Position gas control switch to the “ON” position and adjust the thermostat dial to call for heat. Is there 10 to 13VAC between the red wire leading to the blower temperature switch and the green ground wire? Blower must be running during this voltage check (see photo 15).

Y

N

Is LED on gas valve flash- Y

 

 

ing the “heartbeat” code

 

(alternating bright/dim)?

N

Verify 115VAC to gas con-

trol (see page 41).

N

No voltage from gas control.

Call for technical support.

Determine cause of blower temperature switch activa- tion and correct.

Is there 10 to 13VAC between

the yellow wire leading from the N pressure switch and the green ground wire (see photo 27)?

Y

N

Do you hear or can you see the igniter sparking?

Y

Safety circuit voltage is OK.

If burner does not light, ob- serve LED flash code on gas control and refer to trouble- shooting section on page 17.

Is there continuity through

the blower temperature switch (see page 31)?

Check igniter/sensor (see page

22). Is igniter/sensor OK?

Correct igniter/ sensor problem

Green ground wire

Red sire leading to blower temp. switch

Yellow wire leading from pressure switch

YCheck for loose or broken Manual background wire connection at switch

terminals.

Y

Faulty cord set or gas control

15

Page 42

42

Page 42
Image 42
Bradford-White Corp U4TW50T*FRN, U4TW40T*FRN, U4TW60T*FRN service manual Safety Circuit Voltage Trace, Page