Bradford-White Corp U4TW40T*FRN, U4TW50T*FRN, U4TW60T*FRN service manual Pressure Switch Testing

Models: U4TW60T*FRN U4TW40T*FRN U4TW50T*FRN

1 52
Download 52 pages 25.44 Kb
Page 25
Image 25
Pressure Switch Testing
Gas control power
switch

Pressure Switch Testing

Pilot Inspection, Testing and Replacement (cont’d)

Step 15. Inspect the pilot tubing and pilot orifice for blockages:

a)Remove ferrule nut from the bottom of the pilot assembly using a 7/16" wrench.

b) Remove the pilot tube and pilot orifice.

c)Inspect the pilot tubing and pilot orifice for blockages. Clean or replace, as neces- sary.

Step 16. Reassemble the pilot assembly and install it on the main burner. Reinstall the burner assembly into the combustion chamber. Re- store the gas supply and check for gas leaks.

Step 17. To resume operation, follow the instructions located on the wa- ter heater lighting instruction label. Or, use the lighting instructions located in the water heater installation and operating manual.

Pressure Switch Testing

WARNING

115 volt potential exposure. Use caution making voltage checks to avoid

personal injury.

Step 1. Move the gas control power switch to the “OFF” position.

Step 2. Remove the three screws (Phillips screw driver) from the con- trol access cover on the blower assembly and remove

cover (see photo 1).

Step 3. Carefully remove pres-

sure switch from blower housing (see photo 2).

1

2

Pressure Switch

Page 25

25

Page 25
Image 25