Thermal Well Testing

Thermal Well Testing

CAUTION

Do not use standard multi-meter probes for this testing. Doing so will damage the connector. Use special pin type electronic probes or small diameter wire pins inserted into connector.

Follow the procedure, below, if the water heater gas control has gone into a ECO lock- out (4 flash, 3 second pause). Reset the gas control by rotating the setpoint knob to the minimum setting for at least 6 seconds before returning to the desired water tem- perature setting.

Step 1. Unplug the thermal well connector from the gas control.

Thermal well connector

Step 2. With a multi-meter set to the ohms setting, meas- ure the resistance between the middle and right side wires.

Step 3. With a multi-meter set to the ohms setting, meas- ure the resistance between the middle and left side wires.

Page 34

34

Page 34
Image 34
Bradford-White Corp U4TW40T*FRN, U4TW50T*FRN, U4TW60T*FRN service manual Thermal Well Testing