Blower Temperature Switch Testing (cont’d)

Blower Temperature Switch Testing

Blower Temperature Switch Testing (cont’d)

Switch Setting

Opens on rise @ approximately 165oF

Auto resets on fall @ approximately 160oF

Cool switch to

below 160oF

Disconnect wire leads to switch. Using multi-meter set N

to the ohms setting. Is there

Replace switch

continuity between the switch

terminals?

(see page 33).

Common causes for high

exhaust temperature

Y

 

 

 

 

 

 

N

 

 

Reconnect wire leads and ob-

Y

 

 

 

serve heater operation. Do

Do switch

Y

Exhaust

 

exhaust gas temperatures

 

contacts

 

temperature

rise to or above 170oF with

 

open?

 

is too hot.

vent connected?

 

 

 

 

N

 

 

 

 

Y

Replace switch

 

 

Do switch con-

 

 

tacts open?

 

(see page 33).

 

 

N

Switch OK

1.Vent length is below mini- mum allowable

2.Vent diameter not to speci- fication

3.Restricted dilution air inlet

4.Missing or deteriorated flue baffle

5.Gas pressure is out of specification

Page 32

32

Page 32
Image 32