Bradford-White Corp U4TW40T*FRN, U4TW50T*FRN, U4TW60T*FRN service manual Gas Control Removal, Page

Models: U4TW60T*FRN U4TW40T*FRN U4TW50T*FRN

1 52
Download 52 pages 25.44 Kb
Page 37
Image 37
Gas Control Removal
Unplug the water heater from the wall outlet.
TTW (water heater)
power cord
Step 2.
Move the gas control power switch to the “OFF”
Gas control power
switch
Step 1. position.
Gas Control & Thermal Well Removal From Water Heater (cont’d)
Step 4. Disconnect the pilot tube using a 7/16” wrench and the main burner feedline with a 3/4” wrench from the gas control.
Pilot and main
feedlines
Step 5. Disconnect the wire harnesses and spark igniter/ flame sense wire from the gas control.
Gas control
Spark igniter/flame sensor wire
Step 6. Remove the gas control & thermal well by rotating the flats of the Thermal Well counter clockwise using a 1-5/16”
wrench.Flats of thermal well
Gas Control Removal From Thermal Well
Following the steps below allows for the removal of the gas control from the thermal well without removing the thermal well from the tank.

Gas Control Removal

Page 37

37

Page 37
Image 37
Bradford-White Corp U4TW40T*FRN, U4TW50T*FRN, U4TW60T*FRN service manual Gas Control Removal, Page