Bradford-White Corp U4TW40T*FRN, U4TW50T*FRN, U4TW60T*FRN service manual Blower Removal

Models: U4TW60T*FRN U4TW40T*FRN U4TW50T*FRN

1 52
Download 52 pages 25.44 Kb
Page 43
Image 43
Blower Removal

Blower Removal

Remove the Blower to Gain Access to the Flue Baffle

Step 1.

Move the gas control

Gas control power

p o w e r

 

switch to the “OFF” position.

switch

 

 

TTW (water heater)

 

Step 2.

Unplug the water

power cord

heater

 

from the wall outlet.

Exhaust adapter

Blower mounting

screws

Step 3. Disconnect the vent system from the exhaust adapter on top of blower.

Step 4. Unplug the cord sets from the blower.

Blower cord sets

Step 5. Remove the three blower mounting screws (1/4” nut driver).

Step 6. Remove the blower with gasket from the top of the water heater.

Step 7. Remove the flue baffle from the

Flue baffle