Bradford-White Corp U4TW60T*FRN, U4TW50T*FRN Pilot Inspection, Testing and Replacement cont’d

Models: U4TW60T*FRN U4TW40T*FRN U4TW50T*FRN

1 52
Download 52 pages 25.44 Kb
Page 23
Image 23
Pilot Inspection, Testing and Replacement (cont’d)

Pilot Maintenance

Pilot Inspection, Testing and Replacement (cont’d)

Step 2.

Unplug the water heater

TTW (water heater)

from the wall outlet.

power cord

Step 3.

Turn off the gas supply to the water heater.

Step 4.

Remove the outer door.

Outer Door

Step 5. Remove the (4) 1/4” hex drive screws holding the right side inner door in place.

(4) 1/4” hex drive

screws

Step 6. Disconnect the pilot tube using a 7/16” wrench and the main burner feedline with a 3/4” wrench from the gas control.

 

 

Pilot and main

 

 

feedlines

Step 7.

Disconnect the spark igniter/flame sensor

wire from gas control.

Gas control

Spark igniter/flame

sensor wire

Right side inner door

Page 23

23

Page 23
Image 23
Bradford-White Corp U4TW60T*FRN, U4TW50T*FRN Pilot Inspection, Testing and Replacement cont’d, Pilot Maintenance