Specifications
Vent Tables
Venting Specifications for:
48Gallon
65Gallon
3” Diameter (7.6 cm) PVC Vent Connector Lengths
Terminating | # of Elbows | Maximum Straight | Minimum Straight | |
Length ft (m) | Length ft (m) | |||
|
| |||
|
|
|
| |
Through the Wall | 1 | 55 (16.8) | 2 (0.6) | |
|
|
|
| |
Through the Wall | 2 | 50 (15.2) | 2 (0.6) | |
|
|
|
| |
Through the Wall | 3 | 45 (13.7) | 2 (0.6) | |
|
|
|
| |
Through the Wall | 4 | 40 (12.2) | 2 (0.6) | |
|
|
|
| |
|
|
|
| |
Through the Roof | 0 | 60 (18.3) | 7 (2.1) | |
|
|
|
| |
Through the Roof | 1 | 55 (16.8) | 7 (2.1) | |
|
|
|
| |
Through the Roof | 2 | 50 (15.2) | 7 (2.1) | |
|
|
|
| |
Through the Roof | 3 | 45 (13.7) | 7 (2.1) | |
|
|
|
|
4” Diameter (10.2 cm) PVC Vent Connector Lengths
Terminating | # of Elbows | Maximum Straight | Minimum Straight | |
Length ft (m) | Length ft (m) | |||
|
| |||
|
|
|
| |
Through the Wall | 1 | 175 (53.3) | 10 (3.1) | |
|
|
|
| |
Through the Wall | 2 | 170 (51.8) | 10 (3.1) | |
|
|
|
| |
Through the Wall | 3 | 165 (50.3) | 10 (3.1) | |
|
|
|
| |
Through the Wall | 4 | 160 (48.8) | 10 (3.1) | |
|
|
|
| |
Through the Wall | 5 | 155 (47.2) | 10 (3.1) | |
|
|
|
| |
|
|
|
| |
Through the Roof | 0 | 180 (54.9) | 15 (4.6) | |
|
|
|
| |
Through the Roof | 1 | 175 (53.3) | 15 (4.6) | |
|
|
|
| |
Through the Roof | 2 | 170 (51.8) | 15 (4.6) | |
|
|
|
| |
Through the Roof | 3 | 165 (50.3) | 15 (4.6) | |
|
|
|
| |
Through the Roof | 4 | 160 (48.8) | 15 (4.6) | |
|
|
|
|
Page 10