Specifications

 

Power Supply

Dedicated 115VAC, 60 Hz, 15A.

 

 

 

 

 

 

Gas Supply Pipe

Minimum 1/2” NPT (schedule 40 black iron pipe recommended).

 

 

 

 

 

 

Approved Gas Type

Natural Gas.

 

 

 

 

 

 

Gas Pressure

6.0” W.C. minimum, 11.0” W.C. maximum.

 

 

 

 

 

 

Venting System

Power vent through the wall or vertical through the roof.

 

 

 

 

 

 

Approved Vent Materials

PVC, CPVC or ABS.

 

 

 

 

 

 

Minimum clearance for

18” from top, 24” from front, 4” sides and rear.

 

 

Servicing

 

 

 

 

 

 

 

 

 

Water Supply Pressure

150 PSI maximum allowable working pressure. Check local codes for

 

 

supply pressure.

 

 

 

 

 

 

 

 

 

TCO Limit

Residential 118oF (87oC), Commercial 199oF (93oC).

 

 

 

 

 

 

Residential Temperature

60oF (16oC) to 160oF (71oC) (approximate temperatures).

 

 

Set Point Range

 

 

 

Commercial Tempera-

80oF (27oC) to 180oF (82oC) (approximate temperatures).

 

 

ture Set Point Range

 

 

 

 

 

 

 

 

 

Blower Temperature

Normally closed, opens @ 165oF (74oC), auto reset @130oF (54oC)

 

 

Switch

 

 

 

 

 

 

 

 

 

 

UTW1 Models:

 

 

 

Normally open, closes on vacuum increase @ -0.68, opens on vacuum

 

 

 

decrease @ -0.65

 

 

 

U4TW Models:

 

 

Pressure Switch

Normally open, closes on vacuum increase @ -0.83, opens on vacuum

 

 

 

 

 

 

decrease @ -0.80

 

 

 

U2TW & UTW4 Models:

 

 

 

Normally open, closes on vacuum increase @ -1.28, opens on vacuum

 

 

 

decrease @-1.25

 

 

 

 

 

 

 

U1TW & U4TW Models:

 

 

Blower

115VAC, 60Hz, 3.1 amps, 3000 RPM, 42 CFM @ 1.5” W.C.

 

 

U2TW & UTW4 Models:

 

 

 

 

 

 

115VAC, 60Hz, 3.1 amps, 3000 RPM, 68 CFM @ 0.4” W.C.

 

 

 

 

 

Page 8

8

Page 8
Image 8