TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

ODS/pilot lights but flame

1. Control knob not fully pressed in

1.

Press in control knob fully

goes out when control knob is

2. Control knob not pressed in

2.

After ODS/pilot lights, keep

released

 

long enough

 

control knob pressed in 30

 

3.

Safety interlock system has

 

seconds

 

3.

Wait one minute for safety in-

 

 

been triggered

 

terlock system to reset. Repeat

 

4.

Equipment shutoff valve not

 

ignition operation

 

4.

Fully open equipment shutoff

 

 

fully open

 

valve

 

5.

Thermocouple connection

5.

Hand tighten until snug, then

 

 

loose at control valve

 

tighten 1/4 turn more

 

6.

Pilot flame not touching ther-

6.

A) Contact local natural or

 

 

mocouple, which allows ther-

 

propane/LP gas company

 

 

mocouple to cool, causing

 

B) Clean ODS/pilot (see

 

 

pilot flame to go out. This

 

 

 

problem could be caused by

 

Cleaning and Maintenance,

 

 

one or both of the following:

 

page 17) or replace ODS/pilot

 

 

A) Low gas pressure

 

assembly

 

 

B) Dirty or partially clogged

 

 

 

 

ODS/pilot

 

 

 

7.

Thermocouple damaged

7.

Replace pilot assembly

 

8.

Control valve damaged

8.

Replace control valve

 

 

 

 

Burner does not light after

1. Burner orifice is clogged

1.

Clean burner (see Cleaning

ODS/pilot is lit

 

 

 

and Maintenance, page 17)

 

 

 

 

or replace burner orifice

 

2.

Inlet gas pressure is too low

2.

Contact local natural or pro-

 

 

 

 

pane/LP gas company

 

 

 

 

Delayed ignition of burner

1. Manifold pressure is too low

1.

Contact local natural or pro-

 

 

 

 

pane/LP gas company

 

2.

Burner orifice is clogged

2.

Clean burner (see Cleaning

 

 

 

 

and Maintenance, page 17)

 

 

 

 

or replace burner orifice

 

 

 

 

Burner backfiring during com-

1. Burner orifice is clogged or

1.

Clean burner (see Cleaning

bustion

 

damaged

 

and Maintenance, page 17)

 

 

 

 

or replace burner orifice

 

2.

Burner damaged

2.

Replace burner

 

3.

Gas regulator defective

3.

Replace gas regulator

116292-01D

www.desatech.com

19

Page 19
Image 19
Desa LSL18NT, LSL18PT, SL18NT, SL18PT, VSL18NT, VSL18PT ODS/pilot lights but flame, Press in control knob fully