CONNECTING TO GAS SUPPLY
WARNING: This appliance re- quires a 1/2" NPT (National Pipe Thread) inlet connection to the pressure regulator.
WARNING: A qualified service person must connect heater to gas supply. Follow all local codes.
Installation Items Needed
Before installing heater, make sure you have the items listed below.
• piping (check local codes) | |
• | sealant (resistant to propane/LP gas) |
• | equipment shutoff valve * |
Back View
Back Stove
Panel
Product
Identification
Label
| Side View |
| |
Front |
| Gas | |
of | Gas Inlet | Log | |
Stove |
| ||
Connection Heater | |||
Unit | |||
Access |
| ||
|
|
Figure 17 - Gas Regulator Location and Gas Line Access Into Stove Cabinet
Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 18, MSVFBNR series, or Figure 19, MSVFBN series).
IMPORTANT: Install equipment shutoff valve in an accessible location. The equip- ment shutoff valve is for turning on or shutting off the gas to the appliance.
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.
• test gauge connection * | |
• | sediment trap |
• | tee joint |
• | pipe wrench |
*An CSA/AGA
The gas inlet connection for the stove heater is located on the lower
17.Make sure gas log heater is secured to the stove cavity assembly.
WARNING: Never connect heater to private
CAUTION: Use only new, black iron or steel pipe.
CSA/AGA
Equipment Shutoff Valve
With 1/8" NPT Tap*
Approved Flexible Gas Hose (if allowed by local codes)
Gas Control
3" Minimum
Figure 18 - Gas Connection (MSVFBNR Series)
From Gas Meter (5" W.C.** to 10.5" W.C. Pressure)
Sediment Tee Joint |
| |
Trap | Pipe |
|
Nipple |
| |
| 3" Minimum | |
| Cap | |
|
|
From Gas Meter (5" W.C.** to 10.5" W.C. Pressure)
Tee Joint
Pipe Nipple SedimentTrap
Cap
CSA/AGA
Equipment Shutoff Valve With
1/8" NPT Tap*
Approved Flexible Gas Hose (if allowed by local codes)
Gas
Regulator
codes. Use pipe of 1/2" diameter or greater to allow proper gas vol- ume to heater. If pipe is too small, undue loss of pressure will occur.
Figure 19 - Gas Connection (MSVFBN Series)
*Purchase the optional CSA/AGA
** Minimum inlet pressure for purpose of input adjustment. | Continued |