Desa MSVFBP installation manual Connecting To Gas Supply, Installation Items Needed, Continued

Models: MSVFBP

1 32
Download 32 pages 36.29 Kb
Page 11
Image 11
CONNECTING TO GAS SUPPLY

OWNER’S MANUAL

INSTALLATION

Continued

CONNECTING TO GAS SUPPLY

Installation Items Needed WARNING: This appliance re- quires a 1/2" NPT (National Pipe Thread) inlet connection to the pressure regulator.

Manual background WARNING: A qualified service person must connect heater to gas supply. Follow all local codes.

Back View

Back Stove

Panel

Product

Identification

Label

Side View

 

 

Front

 

 

of

 

Gas

Stove

Gas Inlet

Log

Unit

Heater

Connection

 

 

 

Access

 

The installer must supply an external regu- lator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incom- ing gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure

18.Pointing the vent down protects it from freezing rain or sleet.

Manual background WARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

Manual background CAUTION: Never connect heater directly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator be- tween the heater and propane/LP supply.

Installation Items Needed

Before installing heater, make sure you have the items listed below.

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

*An CSA/AGA design-certified equip- ment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connec- tion. Purchase the optional CSA/AGA de- sign-certified equipment shutoff valve from your dealer. See Accessories, page 23.

The gas inlet connection for the stove heater is located on the lower right-hand side of the stove when viewed from the front of the unit. The gas connection can be made either through the bottom right side or through the lower back opening as illustrated in Figure

17.Make sure gas log heater is secured to the stove cavity assembly.

Figure 17 - Gas Regulator Location and Gas Line Access Into Stove Cabinet

Propane/

 

LP

 

Supply

External

Tank

Regulator

 

Vent

 

Pointing

 

Down

Figure 18 - External Regulator With Vent Pointing Down

CSA/AGA Design-Certified

Equipment Shutoff Valve With

1/8" NPT Tap*

Approved Flexible Gas Hose (if allowed by local codes)

Gas Control

3" Minimum

Manual background CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 19, MSVFBPR series, or Figure 20, page 12, MSVFBP series).

IMPORTANT: Install equipment shutoff valve in an accessible location. The equip- ment shutoff valve is for turning on or shutting off the gas to the appliance.

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

From External

Regulator (11"

W.C.** to 14" W.C.

Pressure)

Tee Joint

Pipe Nipple

Sediment

Trap

Cap

 

Figure 19 - Gas Connection(MSVFBPR Series)

Continued

105986

11

For more information, visit www.desatech.com

Page 11
Image 11
Desa MSVFBP installation manual Connecting To Gas Supply, Installation Items Needed, Continued