Desa MSVFBP Operating Heater, For Your Safety Read Before Lighting, Sun Valley Stove Company

Models: MSVFBP

1 32
Download 32 pages 36.29 Kb
Page 14
Image 14
OPERATING

SUN VALLEY STOVE COMPANY

VENT-FREE PROPANE/LP GAS STOVE HEATER

OPERATING

HEATER

FOR YOUR SAFETY

READ BEFORE

LIGHTING

FOR YOUR SAFETY WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been un- der water.

AUTO

OFF

ON

LIGHTING

INSTRUCTIONS

MSVFBPR REMOTE-READY MODELS

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Open window to vent smell. This will only last a few hours.

1.STOP! Read the safety information, column 1.

2.Make sure equipment shutoff valve is fully open.

3.Set switch to OFF position.

LIGHTING WARNING: Burners will come on automatically within one minute when the selector switch is in the ON position after the pilot is lit.

4.Press in and turn control knob clock-

wise Manual background to the OFF position.

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation column 1. If you don’t smell gas, go to the next step.

6.Press in and turn control knob coun-

terclockwise Manual background to the PILOT position. Press in control knob for five (5) seconds (see Figure 26).

Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.

Flame Adjustment Knob

Control Knob

IH

 

O

 

F

N

F

O

P

LO

LI

TO

7.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep press- ing ignitor button until pilot lights.

Note: If pilot does not stay lit, con- tact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Light- ing Procedure on page 15.

8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4 through 8.

9.Slightly push in and turn control

knob counterclockwise Manual background to the ON position.

10.Wait one minute and switch selector switch to the ON position to light burners. Note: AUTO is only func- tional when using GWMT1 or GWMS2 optional accessories.

11.Set flame adjustment knob to any level between HI and LO.

Manual background CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve.

Manual background WARNING: Make sure the selector switch is in the OFF po- sition when you are away from home for long periods of time. Heater will come on automati- cally with selector switch in the ON position.

Thermocouple

 

Ignitor

Pilot Burner

Electrode

 

Ignitor Button Selector Switch in OFF Position

 

Figure 26 - Control Knob and Ignitor Button Location (Shown as Supplied,

Figure 27 - Pilot

 

No Control Options)

 

For more information, visit www.desatech.com

14

105986

Page 14
Image 14
Desa MSVFBP Operating Heater, For Your Safety Read Before Lighting, Lighting Instructions Msvfbpr Remote-Readymodels