SUN VALLEY STOVE COMPANY
VENT-FREE PROPANE/LP GAS STOVE HEATER
OPERATING
HEATER
Continued
•In the AUTO mode, the thermostat in the
IMPORTANT: This remote control has been specially engineered to take an air temperature sample ev- ery minute in the auto mode. It will not respond immediately to the temperature setting being turned up or down.
IMPORTANT: The
3.To turn the burner off, press the AUTO/ON/OFF button until OFF lights. The pilot will remain lit.
IMPORTANT: To turn the pilot off, manually turn the control knob on the heater to the OFF position.
LIGHTING
INSTRUCTIONS
MSVFBP VARIABLE
MANUAL-CONTROL
MODELS
NOTICE: During initial operation of new heater, burning logs will give off a
1.STOP! Read the safety information page 14, column 1.
2.Make sure equipment shutoff valve is fully open.
3.Press in and turn control knob clock-
wise to the OFF position.
4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information on page 14, column 1 . If you don’t smell gas, go to the next step.
5.Slightly depress and turn control
knob counterclockwise
Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.
6.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the burner (see Figure 16, page 10). If needed, keep pressing ignitor button until pilot lights.
Note: If pilot does not light, contact a qualified service person or gas sup- plier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Light- ing Procedure.
Ignitor Button | Control Knob |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Figure 30 - Control Knob and Ignitor Button Location
Pilot Burner
Ignitor
Electrode
Thermocouple
Figure 31 - Pilot
7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
Note: If pilot goes out, repeat steps 3 through 7.
•If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.
8.Slightly depress and turn control
knob counterclockwise
VARIABLE CONTROL
OPERATION
The variable control valve can be set to any heat setting and flame height desired, by simply turning the control knob until that setting is attained. Even the lowest setting provides realistic, dancing yellow flames. Selecting higher settings produces greater heat output. This results in in- creased heating comfort.
WARNING: Do not operate heater between PILOT and HIGH positions.
CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve
TO TURN OFF GAS TO
APPLIANCE
Shutting Off Heater
1.Press in and turn control knob clock-
wise Clockwise to the HIGH position.
2.Turn the control knob clockwise Clockwise to the PILOT position.
3.Press in control knob and turn clock-
wise Clockwise to the OFF Position.
Shutting Off Burners Only (pilot stays lit)
1.Turn the control knob clockwise Clockwise to the HIGH position.
2.Press in and turn control knob clock-
wise Clockwise to the PILOT position.
For more information, visit www.desatech.com | 16 | 105986 |