| Air Intake Filter |
| |
Air Output, Air Intake, | Filter End |
| ||
and Lint Filters |
| |||
Cover | Fan Guard | |||
1. | Remove upper shell (see |
| ||
|
| |||
| page 10). |
|
| |
2. | Remove filter end cover |
|
| |
| screws using 5/16" nut- |
|
| |
| driver. | Lint Filter |
| |
3. | Remove filter end cover. |
| ||
Air Output |
| |||
4. | Replace air output and lint |
| ||
Filter |
| |||
| filters. |
| ||
|
|
| ||
5. | Wash or replace air intake |
|
| |
| filter (see Preventative |
|
| |
| Maintenance Schedule, | Figure 20 - Air Output, Air Intake, and Lint Filters, | ||
| page 8). | 30/70,000 BTU/Hr Models |
| |
6. | Replace filter end cover. | Air Intake Filter | Fan Guard | |
7. | Replace fan guard and | |||
| (90,000 BTU/Hr | |||
| upper shell. |
| ||
| Filter End | Model Shown) | ||
| IMPORTANT: Do not oil | Cover |
| |
|
|
| ||
| filters. |
|
|
| Lint Filter |
| |
|
| Air Output | |
|
| Filter | |
| Figure 21 - Air Output, Air Intake, and Lint Filters, | ||
| 90/150,000 BTU/Hr Models | ||
Pump Pressure |
|
| |
Adjustment |
| (30/70,000 BTU/Hr Models Shown) | |
1. Remove pressure gauge |
|
| |
plug from filter end cover. | Pressure | Relief | |
2. Install accessory pressure | |||
Gauge | Valve | ||
gauge (part number | Plug |
| |
HA1180). |
|
| |
3. Start heater (see Operation, | Figure 22 - Pressure Gauge Plug Removal | ||
page 7). Allow motor to | |||
| PRESSURE GAUGE PLUG | PFA/OV 006B | |
reach full speed. |
|
|
4.Adjust pressure. Turn relief valve to right to increase
pressure. Turn relief valve |
| Pump | Pressure |
to left to decrease pressure. |
| ||
Model | Gauge | ||
See specifications at right | Pressure |
| |
30,000 BTU/Hr | 2.6 PSI |
| |
for correct pressure for |
| ||
70,000 BTU/Hr | 3.8 PSI |
| |
each model. |
| ||
90,000 BTU/Hr | 4.4 PSI |
| |
5. Remove pressure gauge. |
| ||
150,000 BTU/Hr | 4.9 PSI |
| |
Replace pressure gauge |
| ||
|
|
| |
plug in filter end cover. |
|
| Figure 23 - Adjusting Pump Pressure |
14
099800