Desa PH70EDI, PH30EDI, PH150EDI, PH100EDI owner manual Nozzle

Models: PH100EDI PH150EDI PH70EDI PH30EDI

1 32
Download 32 pages 39.88 Kb
Page 17
Image 17
Figure 30).

Nozzle

 

(150,000 BTU/Hr Model)

Combustion

1. Remove upper shell (see

Chamber

page 10).

 

2.Remove fan (see page 19).

3.Remove spark plug wire

 

from spark plug.

 

Spark Plug

4.

Remove spark plug from

Burner Head

Wire

 

burner head using 13/16"

 

 

 

open-end wrench.

 

 

5.

Loosen flare nut using

 

 

 

3/4" open-end wrench.

 

 

 

Push fuel tube down.

 

 

6.

Remove air line hose from

Screw

 

 

burner head.

Spark

 

 

7.

Remove three screws

 

 

Plug

 

using 5/16" nut-driver and

 

 

 

remove burner head from

 

 

 

combustion chamber.

Air Line Hose

 

8.

Place burner head into vise

Flare Nut

 

 

 

 

and lightly tighten.

Fuel Tube

 

 

 

 

9.Carefully remove nozzle from burner head using 5/8" socket wrench (see

Figure 30).

Figure 29 - Removing Burner Head, 150,000 BTU/Hr Model

10.Blow compressed air thru face of nozzle. This will free any dirt in nozzle area.

11.Inspect nozzle seal for damage.

12.Replace nozzle into burner

head and tighten firmly

Nozzle

 

(9.1-12.4 n-m).

Face

Nozzle

13. Attach burner head to

 

 

Seal

combustion chamber.

 

 

14. Install spark plug in burner

 

Nozzle

head.

 

 

 

15. Attach spark plug wire to

 

 

spark plug.

 

 

16. Attach fuel tube and air

 

 

line hose to burner head.

 

 

Attach flare nut until nut

 

 

seats against fuel tube and

 

Burner

fitting. Tighten 1/4 turn

 

 

Head

more using 3/4" open-end

 

 

wrench (11.3-14.7 n-m).

 

 

17.Replace fan (see page 19).

18.Replace fan guard and upper shell.

Figure 30 - Removing Nozzle, 150,000 BTU/Hr Model

17

099800

Page 17
Image 17
Desa PH70EDI, PH30EDI, PH150EDI, PH100EDI owner manual Nozzle