OPERATION

CAUTION: Do not stand in front of heater while lighting. Stand at the side when lighting the heater.

Use only a 20 lb. propane/LP cylinder (not included). See safety information for proper cylinder selection. Connect the hose/regulator assembly to the cylinder (see Figure 4). The hose should already be connected to the heater. When connecting regulator assembly to cylinder valve, hand tighten nut clockwise to a positive stop. DO NOT use a wrench to tighten. Use of a wrench may damage quick closing coupling nuts and result in a hazardous condition.

20 lb. Propane/LP Cylinder

Hose/Regulator

Assembly

Figure 4 - Connecting Hose/Regulator

Assembly to Propane/LP Cylinder

CHECKING FOR LEAKS

1.Turn heater valve to OFF position.

2.Turn cylinder supply valve fully counter clockwise to OPEN position.

3.Use a soapy water solution to check the connec- tion. For leaks before attempting to light heater. If leak is found, turn cylinder valve to CLOSE and do not use until all leaks are corrected.

LIGHTING INSTRUCTIONS

1.Push heater control knob in and turn counter clockwise to the START position.

2.Push knob in and quickly press IGNITOR button. Repeat until heater is lit.

3.Continue holding knob in for approximately 30 seconds. Heater should remain lit in the LOW heat setting.

4.For more heat, press knob and rotate counter- clockwise to HIGH setting.

5.If RELIGHTING, wait 5 minutes for heater to cool and gas to clear, then follow steps 5 through 8.

SHUTDOWN INSTRUCTIONS

1.Press control knob and rotate clockwise to OFF position.

2.Close propane/LP cylinder valve (rotate knob clockwise).

BURNER OPERATION

Visually inspect burner for proper operation. The burner should glow red with a minimum amount of flame lap after initial firing. If flame lap on burner is excessive, have heater serviced. Pressure may be too high or nozzle/burner may be damaged.

 

Side

 

Correct

View

Incorrect

 

Flame

 

Flame

Pattern

 

Pattern

Figure 5 - Burner Operation

STORAGE

CAUTION: Disconnect heater from propane/LP supply cylinder.

1.Do not store heater while attached to propane/ LP cylinder. Close cylinder valve. Remove the hose/regulator assembly from the propane/LP cylinder by turning the fuel gas connector nut clockwise.

2.Storage of heater inside is permissible only if the cylinder is disconnected and removed from the appliance.

3.Store propane/LP cylinder in safe manner. Refer to Chapter 5 of Standard for Storage and Handling of Liquefied Petroleum Gases, ANSI/ NFPA 58. Follow all local codes. Cylinders must be stored outdoors in a well-ventilated area out of reach of children. Disconnected cyl- inders must have threaded valve plugs tightly installed, and must not be stored in a building, garage or any other enclosed area. Never store cylinders near high heat, open flame, or where temperatures exceed 100° F (38° C).

4.Store in a dry, clean, and safe place.

113530-01A

www.desatech.com

5

Page 5
Image 5
Desa PD35VPA, PL35VPA, PG35VPA, PV35VPA owner manual Operation, Storage