Desa PV35VPA, PL35VPA, PD35VPA, PG35VPA Safety Information, Continued, Clearances from Combustibles

Models: PV35VPA PG35VPA PD35VPA PL35VPA

1 32
Download 32 pages 44.04 Kb
Page 3
Image 3
Continued

SAFETY INFORMATION

Continued

3.Keep appliance area clear and free from com- bustible materials, gasoline, paint thinner, and other flammable vapors and liquids. Dust is combustible. Do not use heater in areas with high dust content.

4.Minimum heater clearances from combustibles: Back: 4 inches (10.2 cm); Sides: 18 inches (.45 m); Top and Front: 36 inches (.91 m) (see Figure 1).

5.Before each use, check heater for leaks. Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

6.Keep propane/LP cylinder below 100° F (38°C).

7.Use only the hose and factory preset regulator provided with the heater. Do not adjust regula- tor as gas leaks may occur.

8.Locate hose properly, keeping it out of path- ways where people may trip over it or in areas where the hose may be subjected to accidental damage.

9.Check hose before each use of heater. Discon- nect hose with 9/16" wrench. Check for tears and abrasions in hose and on regulator. If highly worn or cut, replace with hose specified by manufacturer before using heater.

10.Do not alter heater. Keep heater in its original state. Do not use heater if altered.

11.Locate heater on stable and level surface.

12.Do not operate heater while sleeping or leave heater unattended.

13.Never move, handle, or service a hot or operat- ing heater. Severe burns may result. You must wait 20 minutes after turning heater off.

14.To prevent injury, wear gloves when handling heater.

15.Turn off heater valve and gas supply to heater when not in use.

16.Use only original replacement parts. This heater must use design-specific parts. Do not substi- tute or use generic parts. Improper replacement parts could cause serious or fatal injuries.

17.Certain materials or items, when stored in front of heater, will be subjected to radiant heat and could be seriously damaged.

18.Shut heater off immediately if flashback oc- curs (flame inside burner tube). Have heater serviced.

19.Never attempt to use heater or any compo- nents that have been damaged or exposed to accidental fire.

20.If you smell gas or suspect a leak, shut off propane/LP cylinder valve at once. Ventilate area. Do not strike a match or create any flame or electric spark. Find and correct leak before attempting to light any appliance.

21.Do not block intake air openings.

Any guard or other protective device removed for servicing must be re- placed prior to operating the heater.

Surface temperatures become very hot when operating heater. Children and adults should stay away to avoid burns or clothing ignition.

Young children should be carefully supervised when they are in the area of the heater.

Clothing or other flammable mate- rials should not be hung from the heater, or placed on or near heater.

Installation and repair should be done by a qualified service person. The heater should be inspected before use and at least annually by a qualified service person. More frequent cleanings may be required as necessary. It is imperative that control compartments, burners, and circulating air passageways of the heater be kept clean.

 

36"

 

(.91 m)

18"

4"

(.45 m)

(10.2 cm)

36"

18"

(.91 m)

(.45 m)

Figure 1 - Clearances from Combustibles

113530-01A

www.desatech.com

3

Page 3
Image 3
Desa PV35VPA, PL35VPA, PD35VPA, PG35VPA owner manual Safety Information, Continued, Clearances from Combustibles