SPECIFICATIONS

SPECIFICATIONS

Output Rating (BTU/Hr)

High - 50,000, Med. - 40,000, Low - 30,000

Propane Vapor Fuel Only

Fuel Consumption Gallons (Liters)/Hour Max. 0.54 (2.0), Min. 0.33 (1.2)

Fuel Consumption Pounds (Kilogram)/Hour Max. 2.3 (8.7), Min. 1.4 (5.3)

Supply Pressure To Regulator: Minimum (for input adjustment) - 10 psi (69 kPa), Maximum - 200 psi (1380 kPa)

Regulator Outlet Pressure - 18" WC (46 cm)

Manifold Pressure: High - 13.7" WC (35 cm) Low - 17" WC (43 cm)

Hot Air Output (CFM Approx) - 275 (7.8 m3)

Motor - 3,300 RPM, 1/20 HP

Electric Input - 120 volt/60 hertz

Amperage - 2

Ignition - Manual, Piezo

Ignitor Gap - 0.17" (4.3 mm)

Temperature Range for Operation* -20° F to 85° F (-6.7° C to 29.5° C)

Heater Weight - 13 lbs (6.6 kg)

Shipping Weight - 15 lbs (7.3 kg)

Carton Size - L x W x H

19.4" x 9.75" x 14.75" (49.3 x 24.8 x 37.5 cm)

Heater Size - L x W x H

18.5" x 8.0" x 12.8" (47 x 19.6 x 32.5 cm)

*When running heater in temperatures above 85° F (29.5° C), high internal temperatures may cause thermal limit device to shut down heater.

TECHNICAL SERVICE

You may have further questions about this heater. If so, contact DESA Heating Productsʼ Technical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready.

You can also visit DESA Heating ProductsʼTechni- cal Service web site at www.desatech.com.

REPLACEMENT PARTS

TECHNICAL SERVICE WARNING: Use only original replacement parts. This heater must use design-specific parts. Do not substitute or use generic parts. Improper replacement parts could cause serious or fa- tal injuries. This will also protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they canʼt supply original replacement part(s), call DESA Industries at 1-905-826-8010.

When calling DESA Industries, have ready

your name

your address

model number of your heater

how heater was malfunctioning

purchase date

In most cases, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they canʼt supply original replacement part(s), call DESA Industriesʼ Parts Department at 1-905-826-8010.

When calling DESA Industries, have ready:

model number of your heater

the replacement part number

ACCESSORY

Purchase accessories and parts from your nearest dealer or service center. If your dealer or service center can not supply an accessory or part, call DESA IndustriesʼParts Department at 1-905-826-8010.You can also write to the address listed on the back page of this manual.

FUEL GAS CONNECTOR - LPA4020

Connects regulator to all standard propane tanks. U.L. and A.G.A. listed.

12

www.desatech.com

105339-01C

Page 12
Image 12
Desa RCLP50-F owner manual Specifications, Technical Service, Replacement Parts, Accessory, Parts Under Warranty