INSTALLATION

INSTALLATION

OPERATION WARNING: Review and un- derstand the warnings in the Safety Information section, page

2.They are needed to safely op- erate this heater. Follow all local codes when using this heater.

Manual background WARNING:Testallgaspiping and connections for leaks after installation or servicing. Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

1.Provide propane supply system (see Propane Supply, page 3).

2.Connect fuel gas fitting on hose/regulator assembly to propane tank(s). Turn fuel gas fitting counterclockwise into threads on tank. Tighten firmly using a wrench. IMPORTANT: Position regulator so that hose leaving the regulator is in a horizontal position (see Figure 6). This places the regulator vent in the proper position to protect it from the weather.

3.Connect hose to valve inlet. Tighten firmly using a wrench. You must use the regulator supplied with heater.

4.Open propane supply valve on propane tank(s) slowly. Note: If not opened slowly, excess- flow check valve on propane tank may stop gas flow. If this happens, close propane supply valve and open again slowly.

5.Check all connections for leaks. Apply mix- ture of liquid soap and water to gas joints. Bubbles forming show a leak that must be corrected.

6.Close propane supply valve.

Propane

Regulator

 

Supply Valve

Hose

 

Propane

Fuel Gas

Tank

 

Fitting

Knob

Valve Inlet HoseManual backgroundManual background

Figure 7 - Hose and Inlet Connector

OPERATION

Manual background WARNING: Review and un- derstand the warnings in the Safety Information section, page

2.They are needed to safely op- erate this heater. Follow all local codes when using this heater.

TO START HEATER

1.Follow all installation, ventilation, and safety information.

2.Locate heater on stable and level surface. Make sure strong drafts do not blow into front or rear of heater.

3.Plug power cord of heater into a three-prong, grounded extension cord. Extension cord must be at least 6 ft (2 m). Extension cord must be UL/CSA listed.

Extension Cord Wire Size Requirements

 

Up to 50 ft (15 m), use 18 AWG rated cord.

 

51 to 100 ft (16 to 30 m) long, use 16 AWG

 

rated cord.

 

101 to 200 ft (31 to 60 m) long, use 14 AWG

 

rated cord.

4.

Plug extension cord into a 120 volt/60 hertz,

 

3-hole, grounded outlet. Motor will start. Fan

 

will turn, forcing air out front of heater.

5.

Open propane supply valve on propane tank(s)

 

slowly. Note: If not opened slowly, excess-

 

flow check valve on propane tank may stop

 

gas flow. If this happens, close propane supply

 

valve and open again slowly.

Figure 6 - Regulator Position

105339-01C

www.desatech.com

5

Page 5
Image 5
Desa RCLP50-F owner manual Installation, Operation