TROUBLESHOOTING

TROUBLESHOOTING

OBSERVED FAULT WARNING: Never service heater while it is plugged in, connected to propane supply, operating, or hot. Severe burns and electrical shock can occur.

OBSERVED FAULT

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

Fan does not turn when heater is

1.

No electrical power to heater

1.

Check voltage to electrical

plugged in

 

 

 

outlet. If voltage is good,

 

 

 

 

check heater power cord for

 

 

 

 

breaks

 

2.

Fan hitting inside of heater

2.

Adjust motor/fan guard to

 

 

shell

 

keep fan from hitting inside of

 

 

 

 

heater shell. Bend fan guard if

 

 

 

 

necessary

 

3.

Fan blades bent

3.

Replace fan. See Fan, page 8

 

4.

Defective motor

4.

Replace motor. See Motor,

 

 

 

 

page 7

 

 

 

 

 

Heater will not ignite

1.

User did not follow installa-

1.

Repeat installation and opera-

 

 

tion or operation instructions

 

tion instructions. See Installa-

 

 

properly

 

tion and Operation, page 5

 

2.

No spark at ignitor. To test for

2.

A) Check ignitor wire. Tighten

 

 

spark, follow step 9 under Ig-

 

or reattach loose ignitor wire.

 

 

nitor, page 8. If you see spark

 

See Figure 14, page 8 for

 

 

at ignitor, have heater serviced

 

ignitor wire location

 

 

by qualified service person. If

 

B) Set gap between ignitor

 

 

no spark seen:

 

electrode and target plate to

 

 

A) Loose or disconnected

 

0.17" (4.3 mm)

 

 

ignitor wire

 

C) Tighten nut holding piezo

 

 

B) Wrong spark gap

 

ignitor to base of heater

 

 

C) Piezo ignitor loose

 

D) Replace ignitor electrode.

 

 

D) Bad ignitor electrode

 

See Ignitor, page 8

 

 

 

 

 

Heater shuts down while run-

1.

High surrounding air tem-

1.

This can happen when running

ning

 

perature causing thermal limit

 

heater in temperatures above

 

 

device to shut down heater

 

85° F (29° C). Run heater in

 

2.

Restricted air flow

 

cooler temperatures

 

2.

Check heater inlet and outlet.

 

3.

Damaged fan

 

Remove any obstructions

 

3.

Replace fan. See Fan, page 8

 

4.

Excessive dust or debris in

4.

Clean heater. See Mainte-

 

 

surrounding area

 

nance, page 6

POSSIBLE CAUSE WARNING:Useonlyinareas free of high dust content.

105339-01C

www.desatech.com

9